User’s Manual
36
Table 4-16 Advance configuration parameters description
Import xml file
Import algorithm configuration file as needed. Click Browse… to select the
path where the file is stored, and then click Import to import the file.
Confidence
Filter
Set the range of limiting plate recognition condition, adjustment range is
from 0 to 100.
The lower the confidence level is, the less limited conditions there will be,
and correspondingly the plate is easier to be recognized and false capture
rate becomes higher as well.
The higher the confidence level is, the more limited conditions there will be,
and correspondingly the plate is harder to be recognized and false capture
rate becomes lower as well.
Advanced
Enters customized algorithm expression and realize
customized special
function.
Step 3 Click Confirm.
4.5.1.3 OSD Configuration
4.5.1.3.1 Video OSD
Set OSD information of video channel.
Step 1 Select Setup > ITC > OSD Config > Video OSD.
Figure 4-36 Video OSD
Step 2 Select Font Size.
Step 3 Set channel title and location.
1) Click Channel Title.
2) Select Enable.
3) Enter channel name into the Input channel title box.
4) Drag the yellow box or enter coordinate directly and then set the location of
channel title.
Step 4 Set time title and location.
1) Click Time Title.