EasyManua.ls Logo

Dahua PFH610V-IR - Control and Wiring Instruction

Dahua PFH610V-IR
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
2.2 Control and Wiring Instruction
With LED/wiper module, there are 3 control modes as shown in
Applicable IPC Camera Type
Wiring Instruction
Camera with RS485 control
function.
Control LED and wiper status at WEB
interface. Specific wiring of IPC is shown in
Figure 2-3 Wiring Diagram of IPC Interface
(Remote Mode 1).
Camera without RS485 control
function; N/C interface of the
camera satisfies “LED” and
WIPER” connection.
Control LED and wiper switch through
camera alarm option. Specific wiring is
shown in Figure 2-4 Wiring Diagram of IPC
Interface (Remote Mode 2).
Camera without RS485 control
function; N/C interface of the
camera cannot satisfy LED”
and “WIPER” connection at the
same time.
Control wiper switch through camera alarm,
and control LED switch through LED
photosensitive unit. Specific wiring of IPC is
shown in Figure 2-5 Wiring Diagram of IPC
Interface (Routine Mode).
Table 2-1 and Table 2-2.
Mode
Applicable IPC Camera Type
Wiring Instruction
Remote 1
Camera with RS485 control
function.
Control LED and wiper status at WEB
interface. Specific wiring of IPC is shown in
Figure 2-3 Wiring Diagram of IPC Interface
(Remote Mode 1).
Remote 2
Camera without RS485 control
function; N/C interface of the
camera satisfies “LED” and
WIPER” connection.
Control LED and wiper switch through camera
alarm option. Specific wiring is shown in
Figure 2-4 Wiring Diagram of IPC Interface
(Remote Mode 2).
Routine
Camera without RS485 control
function; N/C interface of the
camera cannot satisfy “LED”
and “WIPER” connection at the
same time.
Control wiper switch through camera alarm,
and control LED switch through LED
photosensitive unit. Specific wiring of IPC is
shown in Figure 2-5 Wiring Diagram of IPC
Interface (Routine Mode).
Table 2-1
Mode
Applicable CVI Camera Type
Wiring Instruction
Remote
Camera with RS485 control
function.
Control LED and wiper status at WEB interface.
Specific wiring is shown in Figure 2-6 Wiring
Diagram of CVI Interface (Remote Mode 1).
Routine
Camera without RS485 control
function.
Control wiper switch through camera alarm,
and control LED switch through LED
photosensitive unit. Specific wiring is shown in
Figure 2-7 Wiring Diagram of CVI Interface
(Routine Mode).
Table 2-2
Camera with RS485 control function means that “Peripheral Management” menu at WEB

Related product manuals