15 English
ECONO Mode Prohibition Setting
WARNING
Always shut off the power supply breaker before starting.
This setting disables the input control signal from the remote controller.
Use this setting when you wish to block reception of input controls (cooling/heating) from indoor unit remote controllers.
Set as follows.
1) Remove the two screws on the side and remove the top plate of the outdoor unit.
2) Remove the electric box cover by sliding it, being careful not to bend the electric box hook.
3) Cut the jumper (J23) of the PCB inside.
4) Go back through step 2) 1). Make sure all components are well secured when doing this.
CAUTION
When returning the electric box cover, be careful not to pinch the fan motor lead wire.
Top plate
Electric
box cover
1) Remove the
two screws.
J26
J24
J23
J6
J22
J8
PCB
PCB
Electric box
3) Cut jumper J23.