EasyManua.ls Logo

Daikin AGZ 160D - VFD Alarm and Status Indicator Meanings; Alarm Content and LED State Interpretation; LO;RE and RUN LED Indicator Meanings

Daikin AGZ 160D
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OMM 1166-1 AGZ 025D through 190D 63
Table 17, Alarm Content
State
Content
Display
Illuminated
When the drive detects an alarm or error
Flashing
When an alarm occurs
When an oPE is detected
When a fault or error occurs during Auto-Tuning
Off
Normal operation (no fault or alarm)
Table 18, LO/RE LED and RUN LED Indictors
LED
Lit
Flashing Slowly
Flashing Quickly
Off
When the operator
is selected for Run
command and
frequency
reference control
(LOCAL)
--
--
When a device other
than the operator is
selected for Run
command and
frequency reference
control (REMOTE)
During run
During
deceleration to
stop
When a Run
command is input
and frequency
reference is 0 Hz
While the drive was set to
LOCAL, a Run command
was entered to the input
terminals then the drive was
switched to REMOTE.
A Run command was
entered via the input
terminals while the drive was
not in the Drive Mode.
During deceleration when a
Fast Stop command was
entered.
The drive output is shut of by
the Safe Disable function.
The STOP key was pressed
while drive was running in
REMOTE.
The drive was powered up
with b1-17 = 0 (default) while
the Run command was
active.
During stop
Examples

Table of Contents

Related product manuals