4 | Operation
User reference guide
34
EABH/X16D + EAVH/X16S(U)18+23D
Daikin Altherma 3 H F+W
4P556071-1D – 2022.03
4 Select the schedule that you currently want to use.
Possible schedules
The table contains the following information:
▪ Schedule/Control: This column shows you where you can consult the currently
selected schedule for the specific control. If needed, you can:
- Select another schedule. See "To select which schedule you currently want to
use"[433].
- Program your own schedule. See "4.7.4Schedule screen: Example"[436].
▪ Predefined schedules: Number of available predefined schedules in the system
for the specific control. If needed, you can program your own schedule.
▪ Activation screen: For most controls, a schedule is only effective if it activated in
its corresponding activation screen. This entry shows you where to activate it.
▪ Possible actions: Actions you can use when programming a schedule. For most
schedules, you can program up to 6 actions per day.
Schedule/Control Description
[1.2] Room > Heating
schedule
Schedule for the desired room
temperature in heating mode.
Predefined schedules: 3
Activation screen: [1.1] Schedule
Possible actions: Temperatures within range.
[1.3] Room > Cooling
schedule
Schedule for the desired room
temperature in cooling mode.
Predefined schedules: 1
Activation screen: [1.1] Schedule
Possible actions: Temperatures within range.
[2.2] Main zone > Heating
schedule
Schedule for the desired leaving
water temperature for the
main zone in heating mode.
Predefined schedules: 3
Activation screen: [2.1] Schedule
Possible actions:
▪ In case of weather-dependent: Shift
temperatures within range.
▪ Otherwise: Temperatures within range
[2.3] Main zone > Cooling
schedule
Schedule for the desired leaving
water temperature for the
main zone in cooling mode.
Predefined schedules: 1
Activation screen: [2.1] Schedule
Possible actions:
▪ In case of weather-dependent: Shift
temperatures within range.
▪ Otherwise: Temperatures within range
[3.2] Additional zone >
Heating schedule
Schedule for when the system
is allowed to heat up the
additional zone in heating
mode.
Predefined schedules: 1
Activation screen: [3.1] Schedule
Possible actions:
▪ Off: When the system is NOT allowed to heat
up the additional zone.
▪ On: When the system is allowed to heat up the
additional zone.