7 | Troubleshooting
User reference guide
54
EABH/X16D + EAVH/X16S(U)18+23D
Daikin Altherma 3 H F+W
4P556071-1D – 2022.03
the Malfunctioning main menu screen, where the user interface will then ask
you to confirm whether the backup heater and/or booster heater can take over
the heat load or not.
When the heat pump fails, or will appear on the user interface.
Possible cause Corrective action
Heat pump is damaged. See "7.1To display the help text in case
of a malfunction"[452].
INFORMATION
When the backup heater or booster heater takes over the heat load, electricity
consumption will be considerably higher.
7.6 Symptom: The system is making gurgling noises after commissioning
Possible cause Corrective action
There is air in the system. Purge air from the system.
(a)
Incorrect hydraulic balance. To be performed by the installer:
1 Perform hydraulic balancing to
assure that the flow is correctly
distributed between the emitters.
2 If hydraulic balancing is not
sufficient, change the pump
limitation settings ([9-0D] and [9-0E]
if applicable).
Various malfunctions.
Check if or is displayed on the
home screen of the user interface. See
"7.1To display the help text in case of a
malfunction"[452] for more
information about the malfunction.
(a)
We recommend to purge air with the air purge function of the unit (to be performed by
the installer). If you purge air from the heat emitters or collectors, mind the following:
WARNING
Air purging heat emitters or collectors. Before you purge air from heat emitters or
collectors, check if or is displayed on the home screen of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to purge air is sufficiently
ventilated. Reason: Refrigerant might leak into the water circuit, and
subsequently into the room when you purge air from the heat emitters or
collectors.