6 Electrical installation
Installation manual
14
ETVH16SU18+23EA6V
Daikin Altherma 3 H HT F
4P644729-1 – 2021.02
6.3 Connections to the indoor unit
Item Description
Power supply (main) See "6.3.1To connect the main power
supply"[415].
Power supply (backup
heater)
See "6.3.2To connect the backup heater
power supply"[416].
Shut-off valve See "6.3.3To connect the shut-off
valve"[417].
Electricity meters See "6.3.4To connect the electricity
meters"[417].
Domestic hot water
pump
See "6.3.5To connect the domestic hot
water pump"[418].
Alarm output See "6.3.6To connect the alarm
output"[418].
Space cooling/heating
operation control
See "6.3.7To connect the space cooling/
heating ON/OFF output"[418].
Changeover to
external heat source
control
See "6.3.8To connect the changeover to
external heat source"[419].
Power consumption
digital inputs
See "6.3.9To connect the power
consumption digital inputs"[419].
Safety thermostat See "6.3.10To connect the safety
thermostat (normally closed
contact)"[420].
Smart Grid See "6.3.11To connect a Smart
Grid"[420].
Room thermostat
(wired or wireless)
See below table.
Wires: 0.75mm²
Maximum running current: 100mA
For the main zone:
â–ª [2.9] Control
â–ª [2.A] Thermostat type
For the additional zone:
â–ª [3.A] Thermostat type
â–ª [3.9] (read-only) Control
Heat pump convector There are different controllers and
setups possible for the heat pump
convectors.
Depending on the setup, you also
need to implement a relay (field
supply, see addendum book for
optional equipment).
For more information, see:
â–ª Installation manual of the heat
pump convectors
â–ª Installation manual of the heat
pump convector options
â–ª Addendum book for optional
equipment
Wires: 0.75mm²
Maximum running current: 100mA
For the main zone:
â–ª [2.9] Control
â–ª [2.A] Thermostat type
For the additional zone:
â–ª [3.A] Thermostat type
â–ª [3.9] (read-only) Control
Item Description
Remote outdoor
sensor
See:
â–ª Installation manual of the remote
outdoor sensor
â–ª Addendum book for optional
equipment
Wires: 2Ă—0.75mm²
[9.B.1]=1 (External sensor =
Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor See:
â–ª Installation manual of the remote
indoor sensor
â–ª Addendum book for optional
equipment
Wires: 2Ă—0.75mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Human Comfort
Interface
See:
â–ª Installation and operation manual of
the Human Comfort Interface
â–ª Addendum book for optional
equipment
Wires: 2Ă—(0.75~1.25mm²)
Maximum length: 500m
[2.9] Control
[1.6] Room sensor offset
WLAN module See:
â–ª Installation manual of the WLAN
module
â–ª Addendum book for optional
equipment
â–ª Installer reference guide
Use the cable delivered with the
WLAN module.
[D] Wireless gateway
WLAN cartridge See:
â–ª Installation manual of the WLAN
cartridge
â–ª Installer reference guide
[D] Wireless gateway
for room thermostat (wired or wireless):
In case of… See…
Wireless room thermostat â–ª Installation manual of the wireless
room thermostat
â–ª Addendum book for optional
equipment
Wired room thermostat
without multi-zoning base
unit
â–ª Installation manual of the wired room
thermostat
â–ª Addendum book for optional
equipment