7 | Unit installation
Installer reference guide
70
EPRA14~18D + ETVH16SU18+23E
Daikin Altherma 3 H HT F
4P644738-1A – 2022.03
c Washer
1 Remove the nut (b) and washer (c) from both transportation stays (a).
2 Remove and discard the washers (c) and transportation stays (a).
3 Re-install the nuts (b) of the compressor mounting bolt and tighten to
10.1N•m of torque.
a Screw
b Transportation stay
4 Remove the screws (a) (5×) from the transportation stay (b). Put 4 screws (a)
aside for later use (see "7.2.4To attach the compressor cover piece"[470]).
5 Remove and discard the transportation stay (b).
7.2.4 To attach the compressor cover piece
Required accessory (delivered with the unit):
Compressor cover piece
1 Put the compressor cover piece on its place. Use the screws (4x) of the
transportation stay to fix it (see "7.2.3 To remove the transportation
stay"[469]).