6 Configuration
Installation manual
25
ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P586453-1B – 2020.01
# Code Description
[2.A] [C–05] External room thermostat type for the
main zone:
1: 1 contact: The used external room
thermostat can only send a thermo
ON/OFF condition. There is no
separation between heating or cooling
demand.
2: 2 contacts: The used external
room thermostat can send a separate
heating/cooling thermo ON/OFF
condition.
6.4.2 Additional zone
Thermostat type
Only applicable in external room thermostat control. For more info
about the functionality, see "6.4.1Main zone"[424].
# Code Description
[3.A] [C–06] External room thermostat type for the
additional zone:
1: 1 contact
2: 2 contacts
6.4.3 Information
Dealer information
The installer can fill in his contact number here.
# Code Description
[8.3] N/A Number that users can call in case of
problems.