6 Electrical installation
Installation manual
21
EBBH/X11+16DF
Daikin Altherma 3 R W
4P643600-1B – 2021.10
Backup
heater type
Backup
heater
capacity
Power
supply
Maximum
running
current
Z
max
*6V 2kW 1N~230V
(a)
9A —
4kW 1N~230V
(a)
17A
(b)(c)
0.22Ω
6kW 1N~230V
(a)
26A
(b)(c)
0.22Ω
2kW 3~230V
(d)
5A —
4kW 3~230V
(d)
10A —
6kW 3~230V
(d)
15A —
*9W 3kW 3N~400V 4A —
6kW 3N~400V 9A —
9kW 3N~400V 13A —
(a)
6V3
(b)
Electrical equipment complying with EN/IEC 61000-3-12
(European/International Technical Standard setting the limits for
harmonic currents produced by equipment connected to public
low-voltage systems with input current >16A and ≤75A per
phase).
(c)
This equipment complies with EN/IEC61000‑3‑11 (European/
International Technical Standard setting the limits for voltage
changes, voltage fluctuations and flicker in public low-voltage
supply systems for equipment with rated current ≤75A) provided
that the system impedance Z
sys
is less than or equal to Z
max
at the
interface point between the user's supply and the public system. It
is the responsibility of the installer or user of the equipment to
ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with
a system impedance Z
sys
less than or equal to Z
max
.
(d)
6T1
Connect the backup heater power supply as follows:
a Factory-mounted cable connected to the contactor of the
backup heater, inside the switch box (K5M)
b Field wiring (see table below)
Model (power
supply)
Connections to backup heater power
supply
*6V (6V3: 1N~230V)
F1B Overcurrent fuse (field supply). Recommended fuse:
4‑pole; 20A; curve 400V; tripping class C.
K5M Safety contactor (in the switch box)
Q1DI Earth leakage circuit breaker (field supply)
SWB Switch box
X6M Terminal (field supply)