Several wiring possibilities
Option
Not mounted in switch box
Wiring depending on model
PCB
Note 1: Connection point of the
power supply for the BUH/BSH
should be foreseen outside the
unit.
Note 1: Connection point of the
power supply for the backup
heater/booster heater should be
foreseen outside the unit.
Backup heater power supply Backup heater power supply
6T1 (3~, 230 V, 6 kW) 6T1 (3~, 230 V, 6 kW)
6V3 (1N~, 230 V, 6 kW) 6V3 (1N~, 230 V, 6 kW)
6WN/9WN (3N~, 400 V, 6/9
kW)
6WN/9WN (3N~, 400 V, 6/9
kW)
User installed options User installed options
Domestic hot water tank Domestic hot water tank
Remote user interface Dedicated Human Comfort
Interface (BRC1HHDA used as
room thermostat)
Ext. indoor thermistor External indoor thermistor
Ext outdoor thermistor External outdoor thermistor
Digital I/O PCB Digital I/O PCB
Demand PCB Demand PCB
Safety thermostat Safety thermostat
Smart Grid Smart Grid
WLAN module WLAN module
WLAN cartridge WLAN cartridge
Bizone mixing kit Bizone mixing kit
Main LWT Main leaving water temperature
On/OFF thermostat (wired) ON/OFF thermostat (wired)
On/OFF thermostat (wireless) ON/OFF thermostat (wireless)
Ext. thermistor External thermistor
Heat pump convector Heat pump convector
Add LWT Additional leaving water
temperature
On/OFF thermostat (wired) ON/OFF thermostat (wired)
On/OFF thermostat (wireless) ON/OFF thermostat (wireless)
Ext. thermistor External thermistor
Heat pump convector Heat pump convector
Position in switch box
English Translation
Position in switch box Position in switch box
Legend
A1P Main PCB
A2P * ON/OFF thermostat (PC=power circuit)
A3P * Heat pump convector
A4P * Digital I/O PCB
A8P * Demand PCB
A11P Main PCB of the MMI (=user interface of the
indoor unit)
A14P * PCB of the dedicated Human Comfort
Interface (BRC1HHDA used as room
thermostat)
A15P * Receiver PCB (wireless ON/OFF
thermostat)
A20P * WLAN module
A30P * Bizone mixing kit PCB
BSK (A3P) Solar pump station relay
CN* (A4P) * Connector
DS1(A8P) * DIP switch
F1B # Overcurrent fuse backup heater
F2B # Overcurrent fuse booster heater
F1U, F2U (A4P) * Fuse 5A 250V for digital I/O PCB
K1A, K2A * High voltage Smart Grid relay
K1M, K2M Contactor backup heater
K3M * Contactor booster heater
K5M Safety contactor backup heater
K*R (A4P) Relay on PCB
M2P # Domestic hot water pump
M2S # 2-way valve for cooling mode
M3S * 3-way valve for space heating/domestic hot
water
PC (A15P) * Power circuit
PHC1 (A4P) * Optocoupler input circuit
Q1L Thermal protector backup heater
Q4L # Safety thermostat
Q*DI # Earth leakage circuit breaker
R1H (A2P) * Humidity sensor
R1T (A2P) * Ambient sensor ON/OFF thermostat
R2T (A2P) * External sensor (floor or ambient)
R5T * Domestic hot water thermistor
R6T * External indoor or outdoor ambient
thermistor
S1S # Preferential kWh rate power supply contact
S2S # Electrical meter pulse input 1
S3S # Electrical meter pulse input 2
S4S # Smart Grid feed-in
S6S~S9S * Digital power limitation inputs
S10S-S11S # Low voltage Smart Grid contact
SS1 (A4P) * Selector switch
TR1 Power supply transformer