4 | Operation
User reference guide
36
EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V+6V+9W
Daikin Altherma 3 R F+W
4P629087-1 – 2020.08
Schedule/Control Description
[7.5.4] User settings >
Electricity price >
Schedule
Schedule for when a certain
electricity tariff is valid.
Predefined schedules: 1
Activation screen: Not applicable
Possible actions: You can use the following
system-defined preset values:
High
Medium
Low
See "4.7.2Setting the energy prices"[431].
Restriction: Only available to
installers.
[9.4.2] Installer settings
> Booster heater > BSH
allowance schedule
Predefined schedules: 1
Activation screen: Not applicable
Possible actions: You can program 2 actions per
day.
Off: Booster heater operation NOT allowed.
On: Booster heater operation allowed.
4.7.4 Schedule screen: Example
This example shows how to set a room temperature schedule in heating mode for
the main zone.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule: overview
Example: You want to program the following schedule:
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Prerequisite: The room temperature schedule is only available if room thermostat
control is active. If leaving water temperature control is active, you can program
the main zone schedule instead.
1 Go to the schedule.
2 (optional) Clear the content of the whole week schedule or the content of a
selected day schedule.
3 Program the schedule for Monday.
4 Copy the schedule to the other weekdays.
5 Program the schedule for Saturday and copy it to Sunday.
6 Give the schedule a name.
To go to the schedule
1 Go to [1.1]: Room > Schedule.
2 Set scheduling to Yes.