7 Installation
Installer reference guide
27
EPGA11~16DAV3 + EABH/X16DA6V+9W
Daikin Altherma – Low temperature split
4P556069-1 – 2018.10
6.4.3 Overview of electrical connections except
external actuators
Normal power
supply
Preferential kWh rate power supply
Power supply is
NOT interrupted
Power supply is
interrupted
1
5
8
0
1
5
0
0
0
2
a
3
1
4
5
8
0
1
5
0
0
0
2
b
3
During preferential
kWh rate power
supply activation,
power supply is NOT
interrupted. The
outdoor unit is turned
off by the control.
Remark: The
electricity company
must always allow the
power consumption
of the indoor unit.
5 3
a
b
14
5
8
0
1
5
0
0
0
5
8
0
1
5
0
0
0
2
During preferential
kWh rate power
supply activation,
power supply is
interrupted
immediately or after
some time by the
electricity company.
In this case, the
indoor unit must be
powered by a
separate normal
power supply.
a Normal power supply
b Preferential kWh rate power supply
1 Power supply for outdoor unit
2 Power supply and interconnection cable to indoor unit
3 Power supply for backup heater
4 Preferential kWh rate power supply (voltage free contact)
5 Normal kWh rate power supply (to power the indoor unit
PCB in the event of power supply interruption of the
preferential kWh rate power supply)
6.4.4 Overview of electrical connections for
external and internal actuators
Item Description Wires Maximum
running
current
Outdoor unit and indoor unit power supply
1 Power supply for
outdoor unit
2+GND
(a)
2 Power supply and
interconnection cable to
indoor unit
3
(g)
3 Power supply for
backup heater
See table below.
4 Preferential kWh rate
power supply (voltage
free contact)
2
(e)
5 Normal kWh rate power
supply
2 6.3A
Optional equipment
6 3‑way valve 3 100mA
(b)
7 Power supply for
booster heater and
thermal protection
(from indoor unit)
4+GND
(c)
8 Power supply for
booster heater (to
indoor unit)
2+GND 13A
Item Description Wires Maximum
running
current
9 Domestic hot water
tank thermistor
2
(d)
10 User interface used as
room thermostat
2
(f)
11 Room thermostat 3 or 4 100mA
(b)
12 Outdoor ambient
temperature sensor
2
(b)
13 Indoor ambient
temperature sensor
2
(b)
14 Heat pump convector 2 100mA
(b)
Field supplied components
15 Shut-off valve 2 100mA
(b)
16 Electricity meter 2 (per meter)
(b)
17 Domestic hot water
pump
2
(b)
18 Alarm output 2
(b)
19 Changeover to external
heat source control
2
(b)
20 Space cool/heat
operation control
2
(b)
21 Power consumption
digital inputs
2 (per input
signal)
(b)
22 Safety thermostat 2
(e)
(a) Refer to name plate on outdoor unit.
(b) Minimum cable section 0.75mm².
(c) Cable section 2.5mm².
(d) The thermistor and connection wire (12m) are delivered
with the domestic hot water tank.
(e) Cable section 0.75mm² till 1.25mm²; maximum length:
50m. Voltage-free contact shall ensure the minimum
applicable load of 15VDC, 10mA.
(f) Cable section 0.75mm² till 1.25mm²; maximum length:
500m. Applicable for both single user interface and dual
user interface connection.
(g) Cable section 1.5mm².
NOTICE
More technical specifications of the different connections
are indicated on the inside of the indoor unit.
Backup heater
type
Power supply Required number of
conductors
*6V 1N~ 230V (6V) 2+GND
3~ 230V (6T1) 3+GND
*9W 3N~ 400V 4+GND
7 Installation
7.1 Overview: Installation
This chapter describes what you have to do and know on-site to
install the system.
Typical workflow
Installation typically consists of the following stages:
1 Mounting the outdoor unit.
2 Mounting the indoor unit.
3 Connecting the water piping.
4 Connecting the electrical wiring.
5 Finishing the outdoor installation.
6 Finishing the indoor installation.