8 Configuration
Installer reference guide
43
EPGA11~16DAV3 + EABH/X16DA6V+9W
Daikin Altherma – Low temperature split
4P556069-1 – 2018.10
Item Description
Additional
zone
h3
h1
h2
h1 Heat emitter type:
: Underfloor heating
: Fancoil unit
: Radiator
h2 Leaving water temperature setpoint
h3 Room thermostat type:
: External control
Hidden: Leaving water temperature control
Domestic
hot water
i1
i2
i1
: Domestic hot water
i2 Measured tank temperature
Malfunction j
or : A malfunction occurred
See "12.4.1To display the help text in case of a
malfunction"on page80 for more information.
8.3.3 Main menu screen
In the home screen, press
to open the main menu screen.
From the main menu, you can access the different setpoint screens
and submenus.
Possible actions on this screen
Go through the list.
Enter the submenu.
Enable/disable breadcrumbs.
Item Description
or
Malfunctioning
Restriction: Only displayed if a malfunction
occurs.
See "12.4.1To display the help text in case
of a malfunction"on page80 for more
information.
Room
Restriction: Only displayed if a room
thermostat is connected to the indoor unit.
Set the room temperature.
Main zone
Shows the applicable symbol for your main
zone emitter type.
Set the leaving water temperature for the
main zone.
Additional zone
Restriction: Only displayed if there are two
leaving water temperature zones. Shows
the applicable symbol for your additional
zone emitter type.
Set the leaving water temperature for the
additional zone (if present).
Space heating/
cooling
Shows the applicable symbol for your unit.
Put the unit in heating mode or cooling
mode. You cannot change the mode on
heating only models.
Tank
Restriction: Only displayed if a domestic
hot water tank is present.
Set the domestic hot water tank
temperature.
Item Description
User settings
Gives access to user settings such as
holiday mode and quiet mode.
Information
Displays data and information about the
indoor unit.
Installer settings
Restriction: Only for the installer.
Gives access to advanced settings.
Commissioning
Restriction: Only for the installer.
Perform tests and maintenance.
User profile
Change the active user profile.
Operation
Turn heating/cooling functionality and
domestic hot water preparation on or off.
8.3.4 Menu screen
Possible actions on this screen
Go through the list.
Enter the submenu/setting.
8.3.5 Setpoint screen
The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Example:
Room temperature screen
Main zone screen
Additional zone screen
Tank temperature screen
a1
d
+
d
e
d
e
c
a2
b1
b2
Possible actions on this screen
Go through the list of the submenu.
Go to the submenu.
Adjust and automatically apply the desired
temperature.
Item Description
Minimum temperature limit a1 Fixed by the unit
a2 Restricted by the installer
Maximum temperature limit b1 Fixed by the unit
b2 Restricted by the installer
Current temperature c Measured by the unit
Desired temperature d Turn the right dial to
increase/decrease.
Submenu e Turn or press the left dial to
go to the submenu.