8 Configuration
Installer reference guide
42
EPGA11~16DAV3 + EABH/X16DA6V+9W
Daikin Altherma – Low temperature split
4P556069-1 – 2018.10
For the setting… Refer to…
Voltage [9.3.2] "Backup heater"on page61
Configuration [9.3.3]
Capacity step 1 [9.3.4]
Additional capacity step 2 [9.3.5]
(if applicable)
Main zone
Emitter type [2.7] "8.4.3Main zone"on
page47
Control [2.9]
Setpoint mode [2.4]
Heating WD curve [2.5] (if
applicable)
Cooling WD curve [2.6] (if
applicable)
Schedule [2.1]
Additional zone (only if [4.4]=1)
Emitter type [3.7] "8.4.4Additional zone"on
page50
Control (read only) [3.9]
Setpoint mode [3.4]
Heating WD curve [3.5] (if
applicable)
Cooling WD curve [3.6] (if
applicable)
Schedule [3.1]
Tank
Heat up mode [5.6] "8.4.6Tank"on page55
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
8.3 Possible screens
8.3.1 Possible screens: Overview
The most common screens are as follows:
+
a
b
c
c2c1
a Home screen
b Main menu screen
c Lower level screens:
c1: Setpoint screen
c2: Detailed screen with values
8.3.2 Home screen
Press the
button to go back to the home screen. You see an
overview of the unit configuration and the room and setpoint
temperatures. Only symbols applicable for your configuration are
visible on the home screen.
6
1.6
bar
18 Feb 2018
22:19
55
18
21
45
f
i
j
h
g
e
d
a
b
c
Possible actions on this screen
Go through the list of the main menu.
Go to the main menu screen.
Enable/disable breadcrumbs.
Item Description
21
21
The temperatures are shown in circles. If the circle
is grey, the corresponding operation (example:
space heating) is currently not active.
Outdoor
unit
a2
a3
a1
a1
: Outdoor unit
a2
: Quiet mode active
a3 Measured ambient temperature
Indoor unit /
domestic
hot water
tank
b1
b2
b1 Indoor unit:
: Floor-standing indoor unit with
integrated tank
: Wall-mounted indoor unit with separated
tank
: Wall-mounted indoor unit
b2 Water pressure
Space
operation
mode
c
: Cooling
: Heating
Disinfection
/ Powerful
d
: Disinfection mode active
: Powerful operation active
Date / time e Current date and time
Holiday f
: Holiday mode active
Main zone
g3
g1
g4
g2
g1 Heat emitter type:
: Underfloor heating
: Fancoil unit
: Radiator
g2 Leaving water temperature setpoint
g3 Room thermostat type:
: Daikin user interface used as room
thermostat
: External control
Hidden: Leaving water temperature control
g4 Measured room temperature