7 Installation
Installation and operation manual
24
EHYKOMB33A
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1H – 2018.10
Which fixation position to use
a
b
a In case to fix on the pipe
b In case to fix on the sleeve
Maximum distance between clamps
Vertical position of pipe Other position of pipe
2000mm 1000mm
Divide the length between the brackets evenly.
Every system MUST contain at least 1 bracket.
Position the first clamp at a maximum of 500 mm from the
gasboiler.
≤1000 mm
≤2000 mm
≤1000 mm