ESIE09-08A Field Setting
Test Operation 91
C Leaving water temperature limits
00 Set point: leaving water maximum temperature 80 37~80 1 °C
01 Set point: leaving water minimum temperature 25 25~37 1 °C
02 Not applicable. Do not change the default value. 20 18~22 1 °C
03 Not applicable. Do not change the default value. 5 5~18 1 °C
D Domestic water heating retention times
00 Set point: minimum time for domestic water
heating
10 5~20 1
01 Set point: maximum time for domestic water
heating
30 10~60 5
02 Set point: interval minimum stop time of
domestic water heating
15 5~30 5
E Service mode
00 Vacuum mode 0 0/1
01 Not applicable. Do not change the default value. 0 (OFF) 0/1
02 Not applicable. Do not change the default value. 0 (OFF) 0/1
03 Not applicable. Do not change the default value. 1 0~2 1
04 Pump only operation 0 0~2 1
First
code
Second
code Setting name
Installer setting at variance with
default value
Default
value Range Step UnitDate Value Date Value