ESIE09-08A
Troubleshooting 127
Part 7 - Troubleshooting
1. Symptom-based Troubleshooting ...................................................................129
2. Troubleshooting by Remote Control...............................................................131
2.1 The INSPECTION / TEST Button ...................................................................131
2.2 Self-diagnosis by Wired Remote Control.........................................................132
2.3 Operation of the Remote Controller’s Inspection / Test Operation Button......133
2.4 Remote Control Service Mode .........................................................................134
2.5 Remote Controller Self-Diagnosis Function ....................................................136
3. Troubleshooting by Indication on the Remote Controller ..............................142
3.1 A1” Indoor Unit: PC Board Defect.................................................................142
3.2 A6” Indoor Unit: Pump Error (M1P) or Other Water System Error ..............143
3.3 A9” Indoor Unit: Malfunction of Moving Part of Electronic Expansion Valve
(K1E) R-410A circuit144
3.4 AE” Indoor Unit: Water Circuit Error ............................................................146
3.5 AJ” Indoor Unit: Malfunction of Capacity Determination Device.................147
3.6 C1” Indoor Unit: Failure of Transmission (Between Indoor unit PC Board and
Control PC Board)148
3.7 “C4” Indoor Unit: Malfunction of Thermistor (R3T) Liquid Thermistor R-410A
150
3.8 C5” Indoor Unit: Malfunction of Tank Thermistor (R2T) .............................151
3.9 C9” Indoor Unit: Return Water Thermistor (R4T).........................................152
3.10 CA” Indoor Unit: Leaving Water Thermistor Error (R5T) ............................153
3.11 CJ” Indoor Unit: Malfunction of Thermostat Sensor in Remote Controller ..154
3.12 E1” Outdoor Unit: PC Board Defect ..............................................................155
3.13 E1” Indoor Unit: PC Board Defect.................................................................156
3.14 E3” Outdoor Unit: Actuation of High Pressure Switch..................................157
3.15 E3” Indoor Unit: Actuation of High Pressure Switch.....................................159
3.16 E4” Outdoor Unit: Actuation of Low Pressure Sensor...................................162
3.17 E4” Indoor Unit: Actuation of Low Pressure Sensor......................................164
3.18 E5 Outdoor Unit: Inverter Compressor Motor Lock.....................................166
3.19 E5 Indoor Unit: Inverter Compressor Motor Lock .......................................167
3.20 E7 Malfunction of Outdoor Unit Fan Motor.................................................168
3.21 E9” Outdoor Unit: Malfunction of Moving Part of Electronic Expansion Valve
170
3.22 E9” Indoor Unit: Malfunction of Moving Part of Electronic Expansion Valve
(K2E) R-134a circuit172
3.23 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature...........................174
3.24 F3” Indoor Unit: Abnormal Discharge Pipe Temperature..............................175
3.25 H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air .........176
3.26 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor (R2T)............177
3.27 J3” Indoor Unit: Malfunction of Discharge Pipe Thermistor (R6T) ..............178
3.28 J5” Outdoor Unit: Malfunction of Thermistor (R3T, R5T) for Suction Pipe 1, 2
179
3.29 J5” Indoor Unit: Malfunction of Thermistor (R7T) for Liquid R-134a..........180
3.30 J6” Outdoor Unit: Malfunction of Thermistor (R6T) for Outdoor Unit Heat Ex-
changer181
3.31 J7” Outdoor Unit: Malfunction of Thermistor (R7T) for Outdoor Unit Liquid
Pipe182