EasyManua.ls Logo

Daikin ALTHERMA HT ERSQ 014 V1 - Page 118

Daikin ALTHERMA HT ERSQ 014 V1
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Setting ESIE09-08A
106 Test Operation
[9] Automatic temperature compensation
If needed, it is possible to adjust some thermistor value of the unit by a correction value. This can be used
as countermeasure for thermistor tolerances or capacity shortage.
The compensated temperature (= measured temperature plus compensation value) is then used for
controlling the system and will be displayed in the temperature read-out mode.
[9-00] Leaving water temperature compensation value
[9-01] Domestic hot water tank compensation value
[9-02] Thermo ON/OFF admission
By changing this value the operation range for space heating operation can be modified.
If the ambient temperature becomes higher than (24°C + the value of [9-02]) no space heating is
possible.
Space heating can be requested as long as the ambient temperature is lower than (20°C + the value of
[9-02]).
Example: [9-02] = –2°C
First
code
Second
code Setting name
Default
value Range Step Unit
9 Automatic temperature compensation
00 Leaving water temperature compensation value 0 –5~5 0.5 °C
01 Domestic hot water tank compensation value 0 –5~5 0.5 °C
02 Thermo ON/OFF admission 0 –5~5 0.5 °C
A No space heating operation possible
B Request for space heating possible
C Hysteresis area
T Ambient temperature
T
20°C–2°C = 18°
C
24°C–2°C = 22°
C
A
B
C
C

Table of Contents