EasyManuals Logo

Daikin D-Series User Manual

Daikin D-Series
479 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #454 background imageLoading...
Page #454 background image
Si18-525B Wiring Diagrams
Appendix 441
2. Wiring Diagrams
2.1 Outdoor Units
RMKS112/140/160DVM, RMKS112/140/160DV1A
POWER SUPPLY
VM
V1A
220-230V~50/60Hz
220-240V~50Hz
THE POSITION OF
COMPRESSOR
TERMINAL
OF WIRE
THE ENTRANCE
L1R
A2P
A3P
N
L
U
YLW
V1T
N
P2
P1
P3
P4
+
-
W
V2R
V
E1
+
C2
Z1C
K1M
X1M
RED
LB
LC
RED
LA
M1C
+
+
U
U
L
RED
N
V
V
3~
MS
R1
+
+
WHT
Z1F
GRN/YLW
C3
C1
W
W
K2R
F1U
BLU
NB
BLU
R2
BLU
NC
NA
N
-
N
-
BRN
N=5
V1R
M1F
X1A
Z2C
WHT
(
RED MARKING
)
3~
MS
PS
X206A
RED
RED
RED
X60A
M2F
Z3C
3~
MS
S1PH
P<
X207A
HAP
WHT
WHT
WHT
WHT
X205A
RED
BLU
X1A
A1P
X25A
1
Y1S
R3T
t
°
X2A
X1M
A
X34A
Y2S
K1R
C/H SELECTOR
X3A
B
K2R
1
R2T
t
°
C
R4T
TO BP UNIT
F1
t
°
E1HC
F2
X6A
BP UNIT
X37A
(
F1
)(
F2
)
R5T
TO OUT/D UNIT
t
°
NOTE
)
8
F1
HAP
X22A
BS1
K5R
H1P
F2
BS2
OFF
OFF
H2P
ON
ON
H3P
t
°
BS3
1
1
H4P
T1R
DS2
DS1
2
2
H5P
3
3
BS4
H6P
4
4
H7P
BS5
X23A
FRONT
A1P
X26A
X45A
X46A
X28A
X44A
X1M
NOTE
)
4
A3P
X24A
X1M
A
t
°
S1NPL
S1NPH
6
6
VIEW A
L1R
Y2E
R1T
Y1E
A2P
M
M
A2P
A3P
HAP
K2R
HAP
K2R
K5R
R2
M2F
E1HC
R2T
R4T
R5T
R3T
BS1~5
Y2E
Y2S
A1P
F1U
H1P~7P
K1M
K1R
L1R
V1T
PS
R1
S1NPL
S1PH
V1R
,
V2R
M1F
M1C
R1T
S1NPH
T1R
Y1E
Y1S
Z1C~3C
Z1F
X1M
X1M
DS1
,
2
C1
,
2
,
3
L-RED
POWER MODULE
(
A2P
)
CRANKCASE HEATER
PUSH BUTTON SWITCH
REACTOR
MOTOR
(
FAN
)
MOTOR
(
FAN
)
MOTOR
(
COMPRESSOR
)
PRESSURES WITCH
(
HIGH
)
PRESSURE SENSOR
(
LOW
)
PILOT LAMP
(
SERVICE MONITOR-ORANGE
)
PILOT LAMP
(
SERVICE MONITOR-GREEN
) (
A2P
)
PILOT LAMP
(
SERVICE MONITOR-GREEN
) (
A1P
)
TRANSFORMER
(
220-240V/24V
)
PRESSURE SENSOR
(
HIGH
)
PRINTED CIRCUIT BOARD
(
NOISE FILTER
)
ELECTRONIC EXPANSION VALVE
(
MAIN
)
ELECTRONIC EXPANSION VALVE
(
SUB COOL
)
FUSE
(
6.3A/250V
)
MAGNETIC RELAY
(
K1M
)
MAGNETIC CONTACTOR
(
M1C
)
CAPACITOR
DIP SWITCH
PRINTED CIRCUIT BOARD
(
INV
)
PRINTED CIRCUIT BOARD
(
MAIN
)
NOISE FILTER
(
WITH SURGE ABSORBER
)
THERMISTOR
(
SUCTION
)
[H2P]PREPARE
,
TEST ------------ FLICKERING
TERMINAL STRIP
(
CONTROL
) (
A1P
)
TERMINAL STRIP
(
POWER SUPPLY
)
SOLENOID VALVE
(
RECEIVER GAS PURGE
)
SOLENOID VALVE
(
HOT GAS
)
SWITCHING POWER SUPPLY
IGBT
(
A2P
)
NOISE FILTER
(
FERRITE CORE
)
MAGNETIC RELAY
(
E1HC
)
MAGNETIC RELAY
(
Y2S
)
MAGNETIC RELAY
(
Y1S
)
RESISTOR
(
CURRENT SENSOR
)
RESISTOR
(
CURRENT LIMITING
)
THERMISTOR
(
AIR
)
THERMISTOR
(
HEAT EXC. OUTLET
)
THERMISTOR
(
HEAT EXC. DEICER
)
THERMISTOR
(
M1C DISCHARGE
)
(
MODE
,
SET
,
RETURN
,
TEST
,
RESET
)
MALFUNCTION DETECTION --- LIGHT UP
T
N-BLU
3D048943
NOTES
)
1.THIS WIRING DIAGRAM IS APPLIED ONLY TO THE OUTDOOR UNIT.
2. :FIELD WIRING.
3. :TERMINAL STRIP
,
:MOVABLE CONNECTOR :FIXED CONNECTOR :TERMINAL
:PROTECTIVE EARTH
(
SCREW
)
:NOISELESS EARTH
4.WHEN USING THE OPTION ADAPTOR
,
REFER TO THE INSTALLATION MANUAL.
5.REFER TO"OPERATION CAUTION LABEL"
(
ON BACK OF FRONT PLATE
),
HOW TO USE BS1~BS5 AND DS1•2 SWITCH.
6.WHEN OPERATING
,
DON’T SHORT CIRCUIT FOR PROTECTION DEVICE.
(
S1PH
)
7.COLORS BLU:BLUE BRN:BROWN GRN:GREEN RED:RED WHT:WHITE YLW:YELLOW.
8.REFER TO THE INSTALLATION MANUAL
,
FOR CONNECTION WIRING TO BP UNIT-OUTDOOR TRANSMISSION F1 F2.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin D-Series and is the answer not in the manual?

Daikin D-Series Specifications

General IconGeneral
HSPF RatingUp to 10.0
Cooling Capacity9, 000 - 36, 000 BTU/h
Heating Capacity9, 000 - 36, 000 BTU/h
Energy Efficiency Ratio (EER)Up to 12.5
Sound Level19 - 50 dB (Indoor), 49 - 60 dB (Outdoor)
Noise Level19 - 50 dB (Indoor), 49 - 60 dB (Outdoor)
Power Supply208/230V, 1-phase, 60Hz