Do you have a question about the Daikin DPSA and is the answer not in the manual?
Refrigerant | R-32 |
---|---|
Coefficient of Performance (COP) | Up to 4.0 |
SEER Rating | 21 |
Sound Level (dB(A)) | 19-45 |
Power Supply | 220-240 V, 50 Hz |
Noise Level (Indoor Unit) | 20 - 45 dB(A) |
Noise Level (Outdoor Unit) | 48-52 dB(A) |
Outdoor Unit Dimensions (W x H x D) | 800 x 550 x 285 mm |
Indoor Unit Weight | 10 kg |
Outdoor Unit Weight | 35 kg |
High-level introduction to Rebel Applied systems, emphasizing flexibility, efficiency, and IAQ.
Details the model naming convention for Daikin Rebel Applied Packaged DX Systems.
Covers construction, thermal properties, and ultra-low air leakage of the cabinet.
Highlights high-efficiency features, ECM fans, and compliance with energy standards.
Explains adaptive cabinet design for customized HVAC solutions, IAQ, and efficiency.
Details filtration, temperature, humidity, and sound for optimal indoor air quality.
Focuses on cost-effectiveness through energy efficiency and easy-to-maintain features.
Highlights features designed to simplify service and reduce operational costs.
Summarizes the standard and customizable features available for Rebel Applied units.
Details unit capacities, materials, and design aspects of the cabinet.
Explains thermal breaks and the cabinet's ultra-low air leakage rates.
Describes access doors and features for easy maintenance and component access.
Covers dual circuits, compressor stages, and hot gas reheat for humidity control.
Details efficiency options like coil selection and fan control for maximizing rebates.
Highlights features engineered to reduce radiated noise from the condenser.
Describes features for managing outside air intake to enhance Indoor Air Quality (IAQ).
Lists various filter options, MERV ratings, and configurations for air purification.
Explains integrated energy recovery systems for heat transfer and efficiency.
Details gas furnace selection, heat exchanger, burner modulation, and control.
Covers electric heat selections, kW ratings, and control capabilities for various applications.
Describes hot water and steam coil features, installation, and system integration.
Discusses fan array construction, balancing, and the benefits of ECM fan technology.
Explains the advantages and features of Electronically Commutated Motors (ECM) for fans.
Details how fan arrays provide operational redundancy and prevent recirculation.
Covers wiring standards, component protection, power connections, and SCCR ratings.
Describes factory-installed air blenders for temperature control and system stability.
Explains factory-installed sound attenuators for noise reduction in sensitive environments.
Details factory-installed steam humidifier distribution grids for humidification needs.
Describes factory-installed UV lights for killing airborne bacteria and molds.
Overview of the advanced MicroTech 4 controller for equipment management and analytics.
Focuses on remote monitoring, data logging, and user interface for equipment performance.
Outlines controller flexibility for unit operation and advanced system functions.
Describes damper control, economizer operation, and fault diagnostics for outdoor air.
Explains the function of energy recovery wheels for heat transfer between air streams.
Provides specifications for components like compressors, fans, and coils by unit size.
Details filter types, sizes, MERV ratings, and quantities for Rebel Applied units.
Presents specifications for gas heat input, output, turndown, and pipe connections.
Details electric heat capacity and control options across different voltages.
Compares standard and highest efficiency ratings (EER/IEER) across unit sizes.
Provides a table of section variations and their corresponding lengths for unit configuration.
Illustrates typical unit configurations for commercial and office applications.
Shows unit layouts for education and 100% outside air applications.
Diagram illustrating required unobstructed clearance around the top of the unit.
Provides an example roof curb drawing and table of variable curb dimensions.
Basic guidelines for unit installation and application analysis.
Details system operating limits, ambient temperatures, and coil face velocities.
Addresses sound performance, ductwork design, and noise attenuation strategies.
Covers scope, references, submittals, maintenance, qualifications, and delivery.
Details cabinet design, insulation, air leakage, and exterior finish requirements.
Covers supply, return, exhaust fans, ECM technology, and motor specifications.
Details wiring, protection, disconnects, SCCR ratings, and voltage utilization.
Covers cooling, heating, and reheat coil types, materials, and testing.
Details hot water and steam coil installation, fabrication, and control valve requirements.
Specifies electric heat construction, safety, and gas heat exchanger and burner features.
Covers filter options, outdoor air control, dampers, and economizer operation.
Details energy recovery systems and condensing section features like head pressure control.
Specifies roof curb requirements and the MicroTech 4 control system.
States the manufacturer's parts-only warranty period and conditions.