EasyManuals Logo

Daikin DCH072 SERIES Installation Instructions

Daikin DCH072 SERIES
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
39
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WIRING DIAGRAMS
RD
BK
POWER DIAGRAM
DCC072
2 SPEED EM
2 STAGE COMP
5. SEE ACCESSORY KIT LITERATURE FOR OPTIONAL CONVENIENCE OUTLET WIRING DIAGRAM.
4 SEE CONTROL DIAGRAM FOR CONTROL TRANSFORMER LOW VOLTAGE CONNECTIONS
3 208/230V SUPPLY POWER UNITS ARE FACTORY CONNECTED TO THE CONTROL TRANSFORMER 240V TAP.
MOVE WIRE CONNECTION FROM 240V TAP TO 208V TAP WHEN 208V POWER SUPPLY IS USED.
2 THE CONTROL TRANSFORMER HAS MULTIPLE HIGH VOLTAGE TAPS.
ENSURE WIRE CONNECTIONS ARE CORRECT FOR UNIT SUPPLY VOLTAGE RATING
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL (USE COPPER CONDUCTORS ONLY).
UNIT TERMINALS ARE NOT DESIGNED FOR OTHER CONDUCTORS
THE USE OF OTHER TYPE CONDUCTORS MAY CAUSE DAMAGE TO THE UNIT
NOTES:
0140L04975-A
GND
L1
L2
L3
LINE VOLTAGE
BK
RD
RD
RD
PU
BK
RD
OR
BK
RD
BK
YL
FC
BK(12)
BK(13)
BK(11)
BK
OR
RD
BK
RD
BK
OR
RD
OR
BK
RD
OR
L1
L2
L3
T1
T2
T3
BC1
BK
BK
RD
L1
L2
L3
T1
T2
T3
BC2
RD
OR
L1
L2
L3
T1
T2
T3
CC
OR
RD
BK
OR
RD
YL
BK
T1
T3
COMP
T2
EM
OR
RD
BK
WH
OR
BL
GY
BL
YL
GY
BL
YL
GR
RD
BK
2,3
4
24V CNTL
VOLTAGE
LINE
VOLTAGE
TR1
LOW VOLTAGE
FIEL
D WIRING
HIGH VOLTAGE
Y2
2ND STAGE
COOL CALL
(OUTPUT)
Y1
1ST STAGE
COOL CALL
(OUTPUT)
W2
2ND STAGE
HEAT CALL
(OUTPUT)
W1
1ST STAGE
HEAT CALL
(OUTPUT)
G
C
R
TB1
CONNECTION
24VAC-PWR
(INPUT)
THERMOSTAT
IN / OUT
24VAC - COM
(INPUT)
FAN CALL
(OUTPUT)
THERMOSTAT CONNECTIONS
YELLOW/
PINK STRIPE
YELLOW
YL/PK
BL/PK
BK
W
IRE CO
D
E
BLACK
BL
BLUE
BR
BROWN
GR
GREEN
GY
GRAY
OR
ORANGE
PK
PINK
PU
PURPLE
RD
RED
WH
WHITE
YL
BLUE/
PINK STRIPE
FACT
O
R
Y
WIRING
LOW VOLTAGE
HIGH VOLTAGE
HIGH VOLTAGE
OPTIONAL
BK
RD
BK
RD
OR
EM
ECON
EVAPORATOR MOTOR
ECONOMIZER
FC
FAN CAPACITOR
COMPRESSOR 2ND STAGE SOLENOID
CS
EVAPORATOR BLOWER
TIME DELAY RELAY
EBTDR
TERMINAL BLOCK 3, LOW VOLTAGE
PLUG / CONNECTOR, MALE
BLOWER CONTACTORBC
PLM
BLOWER RELAY
COMPRESSOR CONTACTOR
CONDENSER MOTOR
COMPRESSOR
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
PLUG / CONNECTOR, FEMALE
TERMINAL BLOCK 1, LOW VOLTAGE
TRANSFORMER 1, CONTROLS
(LINE VOLTAGE / 24VAC)
CC
CM
COMP
HPS
LPS
PLF
TB1
TR1
COMPONENT LEGEND
BR
TB3
E
Q
U
P
I
M
E
N
T
G
R
O
U
N
D
G
N
D
CM
PU
BR
BK
GR
BK
BR
BK
BR
PU
PU
6
6 2 SPEED EVAPORATOR MOTOR: BLACK LEADS FOR HIGH SPEED OPERATION, AND
WHITE / BLUE / ORANGE LEADS FOR LOW SPEED OPERATION.
7 CONDENSER WIRING SHOWN FOR (208/230)V MODELS. WIRE TO WIRE CONNECTIONS NOT PRESENT ON (460/575)V MODELS.
THE CONDENSER MOTOR LEADS CONNECT DIRECTLY TO FAN CAPACITOR / COMPRESSOR CONTACTOR.
7
POWER DIAGRAM FOR DCC072***V
(AIR CONDITIONER, 2 SPD EVAP FAN, 2 STAGE COMP, ALL VOLTAGES)

Other manuals for Daikin DCH072 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin DCH072 SERIES and is the answer not in the manual?

Daikin DCH072 SERIES Specifications

General IconGeneral
BrandDaikin
ModelDCH072 SERIES
CategoryHeat Pump
LanguageEnglish

Related product manuals