DV**PEC / DV**FEC (EEV SERIES AIR HANDLERS)
IOD-4018J
11/2019
INSTALLATION INSTRUCTIONS
1 Important Safety Instructions ............................................................... 2
2 Shipping Inspection ...............................................................................3
2.1 Parts ........................................................................................................3
2.2 Handling ..................................................................................................3
3 Codes & Regulations ............................................................................. 3
4 Replacement Parts.................................................................................3
5 Pre-Installation Considerations ........................................................... 3
5.1 Preparation .............................................................................................. 3
5.2 System Matches ...................................................................................... 3
5.3 Interconnecting Tubing ............................................................................ 3
5.4 Clearances ..............................................................................................3
5.5 Horizontal Applications ............................................................................3
6 Installation Location ............................................................................. 4
6.1 Upow Installation ................................................................................... 4
6.2 Horizontal Left Installation ....................................................................... 4
6.3 Downow/Horizontal Right Installation .................................................... 4
7 Refrigerant Lines ................................................................................... 7
7.1 Tubing Size .............................................................................................. 7
7.2 Tubing Preparation .................................................................................. 7
7.3 Tubing Connections ................................................................................. 8
8 Condensate Drain Lines ........................................................................ 8
9 Ductwork.................................................................................................9
9.1 Return Ductwork ...................................................................................... 9
10 Return Air Filters ..................................................................................9
11 Electric Heat ......................................................................................... 9
12 Electrical and Control Wiring ............................................................ 11
12.1 Building Electrical Service Inspection .................................................. 11
12.2 Wire Sizing .......................................................................................... 11
12.3 Maximum Overcurrent Protection (MOP) ............................................ 11
12.4 Electrical Connections – Supply Voltage ............................................. 11
12.4.1 Air Handler Only (Non-Heat Kit Models) ........................................... 11
12.4.2 Air Handler - Non-Circuit Breaker Heat Kits ..................................... 11
12.4.3 Air Handler With Circuit Breaker Heat Kit ......................................... 11
13 Achieving 1.4% & 2% Low Leakage Rate ........................................ 12
14  Airow Trim ........................................................................................ 12
15 Miscellaneous Start-Up Checklist .................................................... 12
15.1 Auxiliary Alarm Switch .........................................................................13
15.2 Circulator Blower ................................................................................. 14
15.3 Motor Orientation ................................................................................. 14
15.4 Accessory Contacts ............................................................................. 14
16  Troubleshooting .................................................................................. 15
16.1 Electrostatic Discharge (ESD) Precautions ....................................... 15
16.2 Diagnostic Chart ................................................................................. 15
16.3 Fault Recall.........................................................................................15
17 Fully Communicating Daikin System ................................................ 16
17.1 Overview..............................................................................................16
17.2 Airow Consideration ...........................................................................16
17.3 Thermostat Wiring ...............................................................................16
17.3.1 Two-Wire Outdoor and Four-Wire Indoor Wiring ......................... 16
17.4 Network Troubleshooting ..................................................................... 16
17.5 System Troubleshooting ...................................................................... 17
Troubleshooting ........................................................................................ 18
Diagnostic Codes ......................................................................................21
Setting the mode display .......................................................................... 22
Wiring Diagram .......................................................................................... 24
Routine Maintenance ................................................................................ 25
NOTICE
If an “Ed” error is encountered
on startup, verify that the
electric heater DIP switches
have been set to the appropriate 
heater size. See Tables 9 and 10 
for the heater kit airow delivery
and DIP switch settings.
Only personnel that have been trained to install, adjust, service or
repair (hereinafter, “service”) the equipment specified in this manual
should service the equipment. The manufacturer will not be
responsible for any injury or property damage arising from improper
service or service procedures. If you service this unit, you assume
responsibility for any injury or property damage which may result. In
addition, in jurisdictions that require one or more licenses to service
the equipment specified in this manual, only licensed personnel
should service the equipment. Improper installation, adjustment,
servicing or repair of the equipment specified in this manual, or
attempting to install, adjust, service or repair the equipment specified
in this manual without proper training may result in product damage,
property damage, personal injury or death.
RECOGNIZE THIS  SYMBOL 
AS A SAFETY PRECAUTION.
Cancer and Reproductive Harm -
www.P65Warnings.ca.gov
PROP 65 WARNING
FOR CALIFORNIA CONSUMERS
0140M00517-A
Question and Answer IconNeed help?

Do you have a question about the Daikin DV24FECB14 and is the answer not in the manual?

Summary

Important Safety Instructions

Pre-Installation Considerations

System Matches

Ensure system components are manufacturer approved and AHRI listed; unmatched systems are not permitted.

Installation Location

Refrigerant Lines

Tubing Connections

Connect liquid and suction lines, braze joints, and protect components with heat shield.

Condensate Drain Lines

Description

The coil drain pan has primary and secondary drains. Pitch lines 1/4" per foot for free drainage and insulate lines.

Electric Heat

Description

Use only Daikin HKS series heat kits. Calculate temperature rise based on airflow, voltage, and heat kit size.

Electrical and Control Wiring

Wire Sizing

Ensure wire size carries Minimum Circuit Ampacity and allows max 2% voltage drop.

Maximum Overcurrent Protection (MOP)

Install NEC/CEC approved overcurrent protection device sized per MOP.

Electrical Connections - Supply Voltage

Use copper conductors only. Ensure proper grounding and connections.

Miscellaneous Start-Up Checklist

Troubleshooting

Electrostatic Discharge (ESD) Precautions

Disconnect power, discharge body static before touching controls or wires.

Fully Communicating Daikin System

Thermostat Wiring

Use 18 AWG wire; max 250 ft between indoor/outdoor, 125 ft between indoor/thermostat.

Diagnostic Codes

Description

List of 7-segment LED display codes and corresponding error descriptions for troubleshooting.

Wiring Diagram

Description

Specific wiring diagrams for DV**PEC models, including component codes and color codes.

Routine Maintenance Recommendations

Summary

Important Safety Instructions

Pre-Installation Considerations

System Matches

Ensure system components are manufacturer approved and AHRI listed; unmatched systems are not permitted.

Installation Location

Refrigerant Lines

Tubing Connections

Connect liquid and suction lines, braze joints, and protect components with heat shield.

Condensate Drain Lines

Description

The coil drain pan has primary and secondary drains. Pitch lines 1/4" per foot for free drainage and insulate lines.

Electric Heat

Description

Use only Daikin HKS series heat kits. Calculate temperature rise based on airflow, voltage, and heat kit size.

Electrical and Control Wiring

Wire Sizing

Ensure wire size carries Minimum Circuit Ampacity and allows max 2% voltage drop.

Maximum Overcurrent Protection (MOP)

Install NEC/CEC approved overcurrent protection device sized per MOP.

Electrical Connections - Supply Voltage

Use copper conductors only. Ensure proper grounding and connections.

Miscellaneous Start-Up Checklist

Troubleshooting

Electrostatic Discharge (ESD) Precautions

Disconnect power, discharge body static before touching controls or wires.

Fully Communicating Daikin System

Thermostat Wiring

Use 18 AWG wire; max 250 ft between indoor/outdoor, 125 ft between indoor/thermostat.

Diagnostic Codes

Description

List of 7-segment LED display codes and corresponding error descriptions for troubleshooting.

Wiring Diagram

Description

Specific wiring diagrams for DV**PEC models, including component codes and color codes.

Routine Maintenance Recommendations

Daikin DV24FECB14 Specifications

General IconGeneral
Cooling Capacity24, 000 BTU/H
Phase1
Frequency60 Hz
RefrigerantR-410A
Voltage208-230V

Related product manuals