INSTALLATION INSTRUCTIONS
AIR CONDITIONER
DX17VSS AIR CONDITIONING
INSTALLATION & SERVICE REFERENCE
Index
Important Safety InStructIonS ............................................. 1
ShIppIng InSpectIon .............................................................. 1
codeS & regulatIonS .......................................................... 2
featureS.............................................................................. 2
Before InStallatIon .............................................................2
precautIonS for SelectIng a locatIon ................................. 2
precautIonS for InStallatIon ............................................... 3
InStallatIon clearanceS ......................................................3
rooftop InStallatIonS .........................................................3
electrIcal noISe ................................................................. 4
Safety conSIderatIonS......................................................... 4
refrIgerant lIneS ............................................................... 6
refrIgerant lIne connectIonS ............................................. 8
leak teStIng (nItrogen or nItrogen-traced) ...................... 8
SyStem Start-up procedure ................................................ 9
Start-up procedure detaIl .................................................. 9
electrIcal connectIonS ......................................................9
calculate refrIgerant charge BaSed on lIne Set length
... 12
connect aIr condItIoner to SyStem .................................. 13
SyStem Start-up teSt (In caSe of ctk04) ........................ 14
Set thermoStat to charge mode (In caSe of ctk04)
... 17
adjuSt refrIgerant level .................................................20
meaSure SuBcoolIng to verIfy proper charge ................. 20
fIeld SelectaBle BooSt mode (In caSe of ctk04) ........... 21
dehumIdIfIcatIon (In caSe of ctk04) ................................. 24
nIght mode (In caSe of ctk04) ........................................ 25
comfortnet™ SyStem .......................................................28
aIr condItIoner advanced feature menu ........................... 30
WIrIng dIagram ................................................................ 33
teStIng capacItor reSIStance ............................................34
coolIng analySIS chart .................................................... 35
trouBleShootIng ...............................................................36
SettIng the mode dISplay .................................................. 41
7-Segment dISplay ............................................................. 47
aIr condItIonIng homeoWnerS routIne maIntenance
recommendatIonS ........................................................ 49
Start up checklISt ........................................................... 50
Important Safety InStructIonS
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owner’s and installer’s responsibility to read and comply
with all safety information and instructions accompanying
these symbols. Failure to heed safety information increases
the risk of personal injury, property damage, and/or product
damage.
WARNING
HIGH VOLTAGE !
dISconnect all poWer Before ServIcIng.
multIple poWer SourceS may Be preSent. faIlure
to do So may cauSe property damage, perSonal
Injury or death.
WARNING
only perSonnel that have Been traIned to InStall, adjuSt, Ser-
vIce or repaIr (hereInafter, “ServIce”) the equIpment SpecIfIed
In thIS manual Should ServIce the equIpment. the manufacturer
WIll not Be reSponSIBle for any Injury or property damage arIS-
Ing from Improper ServIce or ServIce procedureS. If you ServIce
thIS unIt, you aSSume reSponSIBIlIty for any Injury or property
damage WhIch may reSult. In addItIon, In jurISdIctIonS that re-
quIre one or more lIcenSeS to ServIce the equIpment SpecIfIed In
thIS manual, only lIcenSed perSonnel Should ServIce the equIp-
ment. Improper InStallatIon, adjuStment, ServIcIng or repaIr of
the equIpment SpecIfIed In thIS manual, or attemptIng to InStall,
adjuSt, ServIce or repaIr the equIpment SpecIfIed In thIS manual
WIthout proper traInIng may reSult In product damage, property
damage, perSonal Injury or death.
CAUTION
do not WaSh the aIr condItIoner WIth exceSSIve Water. an elec-
trIc Shock or fIre could reSult.
ShIppIng InSpectIon
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and sub-
sequent investigation is the responsibility of the carrier. Verify
the model number, specications, electrical characteristics,
and accessories are correct prior to installation. The distributor
or manufacturer will not accept claims from dealers for trans-
portation damage or installation of incorrectly shipped units.
English
Français
Español

Questions and Answers

  • L
    Linda PenaAug 18, 2025
    What to do if my Daikin DX17VSS481AA Air Conditioner shows HI PRESSURE C error?
    • J
      Julie MedinaAug 19, 2025
      If your Daikin Air Conditioner displays 'HI PRESSURE C' (Critical), it could be due to several reasons: a blocked or restricted condenser coil, a stop valve not fully open, an overcharge of refrigerant, the outdoor fan not running, an inoperable high-pressure switch (HPS), or a faulty indoor EEV coil. You should check and clean the condenser coil and lines, ensure the stop valve is fully open, verify the refrigerant charge level, inspect the outdoor fan motor and wiring, and check the indoor EEV and its coil. If none of these steps resolve the issue, consider replacing the control board.
  • A
    andrewsdavidAug 20, 2025
    What to do if my Daikin Air Conditioner shows LOW PRESSURE C error?
    • L
      Lisa WarrenAug 21, 2025
      If your Daikin Air Conditioner displays 'LOW PRESSURE C', it could be due to a stop valve not being completely open, a restriction in the refrigerant lines, a low refrigerant charge, a refrigerant leak, an inoperable or improperly connected low-pressure sensor, an indoor fan motor not functioning correctly, or a faulty indoor EEV, EEV coil or control board. Check the opening of the stop valve, look for restrictions in the refrigerant line, check the refrigerant charge level, test for system leaks, check the connection to the low-pressure sensor, and inspect the indoor EEV, EEV coil and control board. Replace components as needed.
  • B
    Blake DavisAug 23, 2025
    What to do if my Daikin DX17VSS481AA shows HI PRESSURE M error?
    • K
      Katherine DavisAug 23, 2025
      If your Daikin Air Conditioner displays 'HI PRESSURE M' (Minor), it might be caused by a blocked or restricted condenser coil, a stop valve that isn't fully open, an overcharge of refrigerant, a non-running outdoor fan, an inoperable high pressure switch (HPS), or a faulty indoor EEV coil. To solve this, check and clean the condenser coil and lines, make sure the stop valve is fully open, verify the refrigerant charge level, inspect the outdoor fan motor and wiring, and check the indoor EEV and its coil. If the problem persists, consider replacing the control board.
  • D
    Denise GarciaAug 26, 2025
    What to do if my Daikin Air Conditioner shows LOW PRESSURE M error?
    • A
      Adam RichardsonAug 26, 2025
      If your Daikin Air Conditioner displays 'LOW PRESSURE M', it could be due to a stop valve not being completely open, a restriction in the refrigerant lines, a low refrigerant charge, a refrigerant leak, an inoperable or improperly connected low-pressure sensor, an indoor fan motor not functioning correctly, or a faulty indoor EEV, EEV coil or control board. Check the opening of the stop valve, look for restrictions in the refrigerant line, check the refrigerant charge level, test for system leaks, check the connection to the low-pressure sensor, and inspect the indoor EEV, EEV coil and control board. Replace components as needed.
  • J
    Joseph HillAug 27, 2025
    What to do if my Daikin DX17VSS481AA Air Conditioner shows COMPRESSOR FAIL error?
    • N
      Nicholas ButlerAug 28, 2025
      If your Daikin Air Conditioner shows a 'COMPRESSOR FAIL' error, it could be due to a stop valve not being completely open, a lost phase in the compressor wire, or compressor motor failure. You should check that the stop valve is fully open, inspect the wire between the control board and the compressor, and inspect the compressor motor for proper function. Replace components as necessary.
  • M
    Mark BennettAug 30, 2025
    What does PCB OR FAN FAIL mean on my Daikin Air Conditioner?
    • F
      finleyericAug 30, 2025
      If your Daikin Air Conditioner displays 'PCB OR FAN FAIL', it could be due to an obstruction in fan rotation, the outdoor fan motor not being connected properly, the outdoor fan not running, a faulty control board, or electrical noise. Check and clean the grille of any debris, check the wiring from the outdoor fan motor to the control board, and check the outdoor fan motor and wiring. If necessary, replace the control board.
  • S
    Sandy WernerSep 1, 2025
    What to do if my Daikin DX17VSS481AA Air Conditioner shows OD CTRL FAIL2 error?
    • J
      Jason WallSep 1, 2025
      If your Daikin Air Conditioner displays 'OD CTRL FAIL2', it could be caused by the outdoor fan motor not being connected properly, a faulty control board or electrical noise. Check the wiring from the outdoor fan motor to the control board and repair if needed. If necessary, replace the control board.
  • J
    Jenna WebbSep 4, 2025
    What does ACE TEMP FAIL mean on my Daikin Air Conditioner?
    • L
      Larry PhillipsSep 4, 2025
      If your Daikin Air Conditioner displays 'ACE TEMP FAIL', it may be due to high or low voltage from the supply, a faulty control board, or noise. Correct any low/high line voltage conditions, contacting your local utility if needed. If that doesn't solve the issue, replace the control board.
  • J
    Jose MedinaSep 6, 2025
    What to do if my Daikin DX17VSS481AA Air Conditioner shows HIGH DISCH TEMP error?
    • H
      hannahhernandezSep 6, 2025
      If your Daikin Air Conditioner displays 'HIGH DISCH TEMP', this may be caused by a discharge thermistor that is inoperable or improperly connected. Check the discharge thermistor resistance and connections, and repair or replace as needed.
  • S
    Sherri ClarkSep 8, 2025
    What to do if my Daikin DX17VSS481AA Air Conditioner shows LOW DISCH TEMP error?
    • A
      Amber FrazierSep 9, 2025
      If your Daikin Air Conditioner displays 'LOW DISCH TEMP', this may be caused by a discharge thermistor that is inoperable or improperly connected. Check the discharge thermistor resistance and connections, and repair or replace as needed.

Summary

Important Safety Instructions

High Voltage Safety Warning

Warning about high voltage and power disconnection before servicing.

Personnel Training Requirement

Warning that only trained personnel should service the equipment.

Caution: Water Usage

Caution against washing the unit with excessive water to prevent shock or fire.

Before Installation Procedures

Installation Precautions

General Safety Considerations

Refrigerant Handling Warnings

Serious warnings about handling refrigerants to prevent injury, explosion, or death.

Refrigerant Cylinder and System Safety

Electrical Safety and Component Warnings

Warnings covering grounding, disposal, qualified personnel, specified parts, and foundation strength.

Refrigerant Line Connections

Leak Testing Procedures

Safety Warnings for Leak Testing

Critical safety warnings regarding pressure regulation and gas usage during leak tests.

System Start-Up Procedure

Detailed Start-Up and Leak Check Steps

Detailed steps for evacuating the system and checking for leaks.

Electrical Connections and Grounding

Warnings about high voltage, correct wiring, NEC compliance, and proper grounding.

Electrical Safety and Wiring

Low Voltage and Communication Wiring

Installer Important Notices

Critical instructions for installers regarding transformer and terminal usage.

Calculate Refrigerant Charge

Refrigerant Charge Calculation Formula

Formula and steps for calculating total refrigerant charge based on line set length.

Connect Air Conditioner to System

Service Valve Opening Sequence

Instructions on the correct sequence for opening service valves to prevent damage.

System Start-Up Test (CTK04)

Procedure for Running System Test

Steps to initiate and run the system verification test on the ComfortNet thermostat.

Equipment Test Menu Operations

Running the System Test

Instructions to select and start the "SYSTEM TEST" from the EQUIP TEST menu.

Set Thermostat to Charge Mode (CTK04)

Charge Mode Operations

Adjust Refrigerant Level

Measure Subcooling for Charge Verification

Procedure for measuring subcooling to verify correct refrigerant charge.

System Diagnostics and Status

Diagnostics and Fault Code Management

Accessing and understanding system faults and diagnostic menus.

System Operation and Setup Menus

System Setup Configuration

System Verification Test Execution

Instructions for running the System Verification Test after installation.

Cooling Setup Options

Wiring Diagram

Testing Capacitor Resistance

Capacitor Testing Safety Warnings

Critical warnings about avoiding charged areas and releasing static electricity.

Cooling Analysis Chart

Cooling Issue Cause Analysis

Chart linking symptoms like temperature deviations and pressure issues to possible causes.

Troubleshooting: Fault Codes E12-E25

OD CTRL FAIL1 and HI PRESSURE C Faults

Troubleshooting steps for OD CTRL FAIL1 and HI PRESSURE C faults, including probable causes.

LOW PRESSURE C and COMPRESSOR FAIL Faults

Troubleshooting steps for LOW PRESSURE C and COMPRESSOR FAIL faults.

PCB OR FAN FAIL and EEV CTRL FAIL Faults

Troubleshooting steps for PCB OR FAN FAIL and EEV CTRL FAIL faults.

Troubleshooting: Fault Codes E26-E45

PRESSURE SENSOR and COIL TEMP FAIL2 Faults

Troubleshooting steps for PRESSURE SENSOR and COIL TEMP FAIL2 faults.

LIQ TEMP FAIL and OD CTRL FAIL3 Faults

Troubleshooting steps for LIQ TEMP FAIL and OD CTRL FAIL3 faults.

HI TEMP CTRL Faults and CURRENT SPIKE

Troubleshooting steps for HI TEMP CTRL faults and CURRENT SPIKE.

Troubleshooting: Fault Codes E47-E56

NO SYS VER TEST and NO CHARGE MODE Faults

Troubleshooting steps for NO SYS VER TEST and NO CHARGE MODE faults.

LINE VOLT CTRL and OD COMM ERROR Faults

Troubleshooting steps for LINE VOLT CTRL and OD COMM ERROR faults.

COMP FAIL MINOR and EEV MINOR Faults

Troubleshooting steps for COMP FAIL MINOR and EEV MINOR faults.

Troubleshooting: E11 RUN SYS TEST Fault

Run System Test Fault Description

Describes the E11 fault indicating an incomplete system test.

Network Troubleshooting

Fault Code History Navigation

7-Segment Display Screens

Unitary Inverter Start-Up Checklist

Pre Start-Up Checklist Items

A checklist of items to verify before initiating the system start-up process.

Unitary Inverter Start-Up Value Entry

Start-Up Values Recording

Instructions for filling in operational values from the thermostat's Status screen.

Daikin DX17VSS481AA Specifications

General IconGeneral
Cooling Capacity (BTU)48000
Heating Capacity (BTU)48000
SEERUp to 17
HSPFUp to 9.5
StagesVariable Speed
RefrigerantR-410A
Voltage208/230
Phase1
Energy Efficiency Ratio (EER)Up to 12.5
Operating Voltage208/230V