Procedure for Software Upload Hydrobox ESIE11-05
204 Service Procedure
After erasing and reprogramming the software, the program will check if the software has been
written correctly (window “Read check”).
The progress can also be checked.
If the check is finished, a window “M16C Flash Start” will appear.
1. Click on OK.
After clicking on “OK”, the window “M16C Flash start” appears again.
1. Click on “Exit” to finish the programming.
The unit has now been reprogrammed.
Step 9 Shut down the power supply again with the main circuit breaker of the unit, to avoid error on
hydrobox.
Step 10 Open the front plate of the hydrobox unit.
Step 11 Disconnect the programming cable on the hydrobox units’ PCB.