EasyManua.ls Logo

Daikin FAY71FAVE - Procedure to Remove Drain Pan

Daikin FAY71FAVE
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure to Remove Drain Pan Si211309E
8 Removal Procedure
7. Procedure to Remove Drain Pan
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
If removing the drain pan:
Carry out pump down,
disconnect the transmission
piping and wiring, and
remove the main unit.
Remove side panels,
operation display cover and
front cover according to their
removal procedures.
1
Remove the bottom
panel.
2
Remove the air
discharge section.
Installation plate
Air discharge
section
Bottom panel
Installation
plate
The bottom panel is fastened to
the unit installation plate by 3
screws.
(2) Bottom panel
(3) Air discharge
section
Comes off if squeezed hard.

Other manuals for Daikin FAY71FAVE