Precautions for New Refrigerant (R-410A) SiUS28-902
177 Precautions for New Refrigerant (R-410A)
8. Weigher for refrigerant charge
Specifications
High accuracy
TA101A (for 10-kg cylinder) = ± 2g
TA101B (for 20-kg cylinder) = ± 5g
Equipped with pressure-resistant sight glass to check liquid refrigerant charging.
A manifold with separate ports for HFCs and previous refrigerants is equipped as a standard
accessory.
Differences
Measurement is based on weight to prevent change of mixing ratio during charging.
Regarding purchasing of service tools, please contact following address.