SiUS28-902_a
iii Table of Contents
3.9 C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger .....................................................................................96
3.10 C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes ........... 97
3.11 C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air ..........98
3.12 CA” Indoor Unit: Malfunction of Thermistor for Discharge Air ................ 99
3.13 CJ” Indoor Unit: Malfunction of
Thermostat Sensor in Remote Controller ............................................100
3.14 E1” Outdoor Unit: P.C.B. Defect ..........................................................101
3.15 E3” Outdoor Unit: Actuation of High Pressure Switch ......................... 102
3.16 E4” Outdoor Unit: Actuation of Low Pressure Sensor ......................... 104
3.17 E5 Inverter Compressor Motor Lock................................................... 106
3.18 E7” Malfunction of Outdoor Unit Fan Motor .........................................108
3.19 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E) .......................................................109
3.20 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature .................111
3.21 F6” Outdoor Unit: Refrigerant Overcharged ........................................112
3.22 H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air .... 113
3.23 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor (R2T)....114
3.24 J5” Outdoor Unit: Malfunction of Thermistor (R3T, R5T) for
Suction Pipe 1, 2 .................................................................................. 115
3.25 J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger..............................................................116
3.26 JA” Outdoor Unit: Malfunction of High Pressure Sensor .....................117
3.27 JC” Outdoor Unit: Malfunction of Low Pressure Sensor ......................119
3.28 L1” Outdoor Unit: Malfunction of P.C.B. ..............................................121
3.29 L4” Outdoor Unit: Malfunction of
Inverter Radiating Fin Temperature Rise ............................................. 122
3.30 L5” Outdoor Unit: Inverter Compressor Abnormal...............................123
3.31 L8” Outdoor Unit: Inverter Current Abnormal ......................................124
3.32 L9” Outdoor Unit: Inverter Start up Error .............................................126
3.33 LC” Outdoor Unit: Malfunction of Transmission between
Inverter and Control P.C.B...................................................................127
3.34 P4” Outdoor Unit: Malfunction of
Inverter Radiating Fin Temperature Rise Sensor.................................128
3.35 U0” Outdoor Unit: Low Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure .....................................................129
3.36 U2” Power Supply Insufficient or Instantaneous Failure ......................131
3.37 U3 Check Operation not Executed .....................................................133
3.38 U4” Malfunction of Transmission between
Indoor Units and Outdoor Units ...........................................................134
3.39
U5” Malfunction of Transmission between
Remote Controller and Indoor Unit ......................................................136
3.40 U8” Malfunction of Transmission between
Main and Sub Remote Controllers.......................................................137
3.41 UE” Malfunction of Transmission between
Centralized Remote Controller and Indoor Unit ...................................138
3.42 UF System is not Set yet .................................................................... 140
3.43 UH” Malfunction of System,
Refrigerant System Address Undefined............................................... 141