Dimensions EDUS091617
10 Split Type Air Conditioners FFQ-Q Series
4.2 Outdoor Unit
RX09/12QMVJU
RX15QMVJU
OUTDOOR AIR THERMISTOR
9/16 (15) 26-9/16 (675) 1-5/16 (50) 5/16 (8)
HANDLE
1/2 (12.4)11-3/16 (284)
13/16 (20)
GROUND
BRAND NAME PLATE
4-1/8 (104)
6-7/16 (164)
21-5/8 (550)
6-1/4 (159)
13/16 (20)
*A
*B
12-1/8 (308)
12-13/16 (326)
*A*A
16-1/16 (408)
1/2 (13)
18-1/2 (470) 3-13/16 (97)
1-1/8 (29)
MINIMUM SPACE FOR AIR PASSAGE
5-7/8 (150)
1-15/16 (50)
5-7/8 (150)
3-15/16 (100)
1-15/16 (50) 1-15/16 (50)
3-15/16 (100)
1-15/16 (50)
UNIT: inch (mm)
11-13/16 (300)
MANUFACTURER'S
LABEL
SERVICE
PORT
STOP VALVE
COVER
LIQUID
STOP VALVE
(φ1/4 (φ6.4) CuT)
GAS
STOP VALVE
(φ3/8 (φ9.5) CuT)
IN CASE OF REMOVING
STOP VALVE COVER
4-HOLES FOR FOUNDATION BOLTS
5/16 OR 3/8 (M8 OR M10)
WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4 (1200)
*A, *B DRAIN OUTLET
WHEN CONDUCTING CONCENTRATED
DRAIN PIPING WORK, ATTACH THE
SUPPLIED DRAIN CAPS.
DRAIN OUTLET
(I,D φ5/8 (φ15.9mm) HOSE FOR CONNECTION
WITH DRAIN JOINT)
3D092206B
HANDLE
34-1/4 (870)9/16 (14) 2-3/4 (70)
OUTDOOR AIR THERMISTOR
1-3/16 (30)12-5/8 (320)1/4 (7)
ELECTRIC WIRE INTAKE
BRAND NAME PLATE
MANUFACTURER'S LABEL
3/4 (19)
28-15/16 (735)
7/8 (23)
9/16 (14.5)
4-15/16 (125)23-5/8 (600)
13-5/8 (346)
7/16 (11
)
14-1/2 (368)
GROUND TERMINAL
MINIMUM SPACE FOR AIR PASSAGE
11-7/16 (291)
3-15/16 (100)
20-11/16 (525)
1-15/16 (50)1-15/16 (50) 1-15/16 (50)
13-3/4 (350)
3-15/16 (100)
3-15/16 (100)
13-3/4 (350)
4-1/8 (105)
6-1/2 (165)
13-3/4 (350)
UNIT: inch (mm)
6-13/16 (173)
4-HOLES FOR FOUNDATION BOLTS
(M8 OR M10)
(INSTALLATION LEG
PITCH)
WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 47-1/4 (1200)
DRAIN OUTLET
(I,D φ5/8 (φ15.9) HOSE FOR
CONNECTION WITH DRAIN JOINT)
LIQUID
STOP VALVE
(φ1/4 (φ6.4) CuT)
GAS
STOP VALVE
(φ1/2 (φ12.7) CuT)
SERVICE
PORT
IN CASE OF REMOVING
STOP VALVE COVER AND
TERMINAL STRIP COVER
C: 3D092224A