EasyManuals Logo

Daikin FT24KV2S User Manual

Daikin FT24KV2S
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
10
AUTO · DRY · COOL · HEAT · FAN Operation
To change the air ow rate setting
Press 5. .
AUTO or COOL or HEAT or FAN operation DRY operation
5 levels of air ow rate setting
from “
” to “ ” plus “
” are available.
The air ow rate setting is not variable.
Indoor unit quiet operation
When the air ow is set to “
”, the noise from the indoor unit will become quieter.
Use this when making the noise quieter.
NOTE
Notes on HEAT operation
Since this air conditioner heats the room by taking heat from outdoor air to indoors, the
heating capacity becomes smaller in lower outdoor temperatures. If the heating effect is
insuf cient, it is recommended to use another heating appliance in combination with the air
conditioner.
The heat pump system heats the room by circulating hot air around all parts of the room.
After the start of HEAT operation, it takes some time before the room gets warmer.
In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In
that case, the system switches into defrosting operation to take away the frost.
During defrosting operation, hot air does not ow out of indoor unit.
A pinging sound may be heard during defrosting operation, which, however does not mean
that the air conditioner has failures.
Note on COOL operation
This air conditioner cools the room by releasing the heat in the room outside.
Therefore, the cooling performance of the air conditioner may be degraded if the outdoor
temperature is high.
Note on DRY operation
The computer chip works to rid the room of humidity while maintaining the temperature as
much as possible. It automatically controls temperature and air ow rate, so manual
adjustment of these functions is unavailable.
Notes on AUTO operation
In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT)
based on the room and outside temperatures and starts the operation.
The system automatically reselects setting at a regular interval to bring the room
temperature to user-setting level.
Note on FAN operation
This mode is valid for fan only.
Note on air ow rate setting
At smaller air ow rates, the cooling (heating) effect is also smaller.
01_EN_3P276856-1B.indb 1001_EN_3P276856-1B.indb 10 12/20/2010 4:17:18 PM12/20/2010 4:17:18 PM

Other manuals for Daikin FT24KV2S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FT24KV2S and is the answer not in the manual?

Daikin FT24KV2S Specifications

General IconGeneral
BrandDaikin
ModelFT24KV2S
CategoryAir Conditioner
LanguageEnglish

Related product manuals