REMOVAL
PROCEDURE
SERVICE MANUAL
Indoor Unit
Inverter / Non-Inverter
Wall Mounted Type
5.0/6.0 kW Class
Si041257EC
Question and Answer IconNeed help?

Do you have a question about the Daikin FTE50NRV16 and is the answer not in the manual?

Summary

Daikin Indoor Unit Removal Procedure

Remove Air Filters

Steps for removing air filters, including hook release and optional filter removal.

Remove Front Panel

Steps for removing the front panel by releasing shafts and pushing it to the side.

Remove Horizontal Blade

Steps to release the center shafts and the left shaft of the horizontal blade.

Remove Vertical Blade Assemblies

Steps to unfasten hooks and remove the vertical blade assemblies from the unit.

Front Grille Removal

Remove Front Grille

Steps for removing the front grille by unscrewing it and unfastening the top hooks.

Electrical Box Disassembly

Remove Service Cover and Electrical Box Cover

Steps to remove the screw, service cover, terminal board, wire fixture, and electrical box cover.

Disconnect Connectors and Remove Electrical Box

Steps to remove the thermistor, disconnect 3 connectors, and lift out the electrical box.

PCBs and Swing Motor Removal

Remove Control PCB

Steps to remove the terminal board screw, release wires, and disconnect the control PCB connector.

Remove Display Receiver PCB and Swing Motor

Steps to unfasten hooks, disconnect PCB connector, and remove the swing motor.

Indoor Heat Exchanger Removal

Remove Indoor Heat Exchanger

Steps for removing drain hose, piping, screws, and detaching the indoor unit from the plate.

Fan Motor and Fan Rotor Replacement

Remove Fan Motor and Fan Rotor

Steps to remove screws, right side plate, and the fan rotor screw.

Remove Bottom Frame and Fan Motor

Steps to unfasten hooks, release the fan rotor from its groove, and remove the fan motor.

Daikin FTE50NRV16 Specifications

General IconGeneral
Cooling Capacity5.0 kW
RefrigerantR32
Indoor Unit Dimensions (W x H x D)990 x 298 x 233 mm
Outdoor Unit Dimensions (W x H x D)845 x 595 x 300 mm
Power Supply230V / 50Hz / 1 Phase