Do you have a question about the Daikin FTE50LV169 and is the answer not in the manual?
Open the front panel, unfasten the filter's center knob, and pull it downward.
Unfasten the filter's hooks on the bottom and upper sides, then remove the filter.
Open the front panel further, release the shafts, and detach the panel.
Remove the screw securing the service cover and detach it.
Remove 3 screws, unfasten 3 hooks on top, and pull the grille upwards.
Open blades, bend slightly, release center shaft, slide left to release right shaft.
Release shafts, unfasten 3 hooks per set, and pull blades rightward.
Remove drip plate, clamp, thermistor, wires, terminal board, and electrical box.
Remove shield plate, signal receiver unit, and control PCB by unfastening hooks.
Remove screws and detach swing motor assemblies for horizontal and vertical blades.
Hold unit, pull drain hose, unscrew flare nuts for gas and liquid piping.
Detach the indoor unit from its installation plate.
Unfasten piping fixture, widen auxiliary piping, unfasten hooks, and lift exchanger.
Remove the two screws and lift the right side plate.
Remove screw for fixing plate and screw for fan rotor.
Remove fan motor, left side plate, and rubber bearing.