Si18-201 Specifications
Specifications 17
Notes:
1.
Refer to Engineering Data Book.
2. The data are based on the conditions shows in the table below.
50Hz 220-230-240V / 60Hz 220-230V
Model
RMX140JZVMB
Cooling Heating
Cooling Capacity (19.0°CWB)
kW 14.5 16.5
kcal/h 12,470 14,190
Power Consumption
W 5,000 6,050
Running Current
A 23.2-22.2-21.3 28.1-26.8-25.7
Casing Color Ivory White
Compressor
Type Hermetically Sealed Scroll Type (Oval Discharge)
Model JT100FAVD
Motor Output W 3,300
Refrigerant
Oil
Model DAPHNE FVC68D
Charge L 1.5
Refrigerant
Type R407C
Charge kg 9.9
Air Flow Rate
m³/min
H 114
L 104
cfm
H 4,024
L 3,671
Fan
Type Propeller
Motor Output W (Upper Side) H : 53 L : 38 (Lower Side) H : 41 L : 30
Running Current A (Upper Side) H : 0.50 L : 0.45 (Lower Side) H : 0.47 L : 0.42
Power Consumption W (Upper Side) H : 93.1 L : 78.8 (Lower Side) H : 81.3 L : 68.8
Power Factor % 100
Starting Current A 29.0
Dimensions (H×W×D) mm 1,345×880×320
Package Dimensions (W×D×H) mm 918×394×1,397
Weight kg 136
Gross Weight kg 145
Operation Sound dBA 53
Piping
Connection
Liquid mm
φ
9.5 (Flare Connection)
Gas mm
φ
19.1 (Flare Connection)
Drain mm
φ
18
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connection 3 For Power Supply, 4 For Interunit Wiring (Included Earth Wiring)
Max. Interunit Piping Length m
115 (Total Main Piping and Branch Piping)
55 (Total Main Piping), 60 (Total Branch Piping)
15 (Max. Length for Each Room)
Amount of Additional Charge g/m Chargeless
Max. Installation Height Difference m 30 (Between Indoor or BP Unit and Outdoor Unit), 15 (Both between Indoor Units and BP Units)
Drawing No. 3D031578
Cooling Heating Piping Length
Indoor ; 27°CDB / 19.0°CWB
Outdoor ; 35°CDB
Indoor ; 21°CDB
Outdoor ; 7°CDB / 6°CWB
Main Piping : 5m
Branch Piping : 3m
(each indoor unit / 71 Class+60 Class)
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
BP Unit
Outdoor Unit
Main Piping
Branch Piping
Indoor Unit
(Q0143)

Table of Contents