Loading...
Printed Circuit Board Connector Wiring Diagram and Name Si18-201
68 Printed Circuit Board Connector Wiring Diagram and Name
1.5 CDX25~60HAV Series, CDK25~60HAV Series
Cooling Only CDK25 / 35 / 50 / 60HAVE (A) (C) (T)
Heat Pump CDX25 / 35 / 50 / 60HAVEA (C), CDX25 / 35 / 50 / 60HAV1NB,
CDX25 / 35 / 50 / 60JV1NB, CDX25 / 35JVEC
Printed Circuit
Board
Printed Circuit Board (1) (Control PCB)
Printed Circuit Board (3) (Intelligent Eye Sensor PCB)
Name of Connector
Note: Other designations
1) S1 Connector for Fan Motor
2) S6 Connector for Swing Motor (Horizontal Flap)
3) S7 Connector for Fan Motor
4) S21 Connector for Centralized Control to 5 Rooms
5) S36 Connector for Control PCB
6) S26 Connector for Signal Receiver PCB
7) S35 Connector for Intelligent Eye Sensor PCB
1) V1 Varistor
2) JA Address Setting Jumper
JB Fan Speed Setting when Compressor is OFF on Thermostat.
JC Power Failure Recovery Function.
3) LED1 (GRN) LED for Operation
4) LED2 (YLW) LED for Timer
5) LED3 (GRN) LED for Intelligent Eye