Si18-201 Outdoor Unit
Removal Procedure 323
5. Detaching the electrical
box
1
Remove the screws
from the electrical box.
2
Lift the electrical box off
the hook at the back,
and draw out the box.
6. Disassembling the
electrical box
1
Disconnect all the
connectors.
"
Make sure to clamp all wire
harness after repair work is
completed.
2
Cut off the clamp at the
wire harness.
Step Procedure Points