Si18-201 Wiring
Caution Before Operation 353
RSW1 RSW2 Remarks Unit
4 1 Current BP 1 Room-A gas pipe temperature Temp. offset 40h
4 2 Current BP 1 Room-B gas pipe temperature Temp. offset 40h
4 3 Current BP 1 Room-C gas pipe temperature Temp. offset 40h
4 4 Current BP 2 Room-A gas pipe temperature Temp. offset 40h
4 5 Current BP 2 Room-B gas pipe temperature Temp. offset 40h
4 6 Current BP 2 Room-C gas pipe temperature Temp. offset 40h
4 7 Current BP 3 Room-A gas pipe temperature Temp. offset 40h
4 8 Current BP 3 Room-B gas pipe temperature Temp. offset 40h
4 9 Current BP 3 Room-C gas pipe temperature Temp. offset 40h
50
5 1 Current BP 1 Room-A indoor temperature Temp. offset 40h
5 2 Current BP 1 Room-B indoor temperature Temp. offset 40h
5 3 Current BP 1 Room-C indoor temperature Temp. offset 40h
5 4 Current BP 2 Room-A indoor temperature Temp. offset 40h
5 5 Current BP 2 Room-B indoor temperature Temp. offset 40h
5 6 Current BP 2 Room-C indoor temperature Temp. offset 40h
5 7 Current BP 3 Room-A indoor temperature Temp. offset 40h
5 8 Current BP 3 Room-B indoor temperature Temp. offset 40h
5 9 Current BP 3 Room-C indoor temperature Temp. offset 40h
60
6 1 Current BP 1 Room-A heat exchange temperature Temp. offset 40h
6 2 Current BP 1 Room-B heat exchange temperature Temp. offset 40h
6 3 Current BP 1 Room-C heat exchange temperature Temp. offset 40h
6 4 Current BP 2 Room-A heat exchange temperature Temp. offset 40h
6 5 Current BP 2 Room-B heat exchange temperature Temp. offset 40h
6 6 Current BP 2 Room-C heat exchange temperature Temp. offset 40h
6 7 Current BP 3 Room-A heat exchange temperature Temp. offset 40h
6 8 Current BP 3 Room-B heat exchange temperature Temp. offset 40h
6 9 Current BP 3 Room-C heat exchange temperature Temp. offset 40h
70
7 1 Current BP 1 Room-A
D signal
D signal
7 2 Current BP 1 Room-B
D signal
D signal
7 3 Current BP 1 Room-C
D signal
D signal
7 4 Current BP 2 Room-A
D signal
D signal
7 5 Current BP 2 Room-B
D signal
D signal
7 6 Current BP 2 Room-C
D signal
D signal
7 7 Current BP 3 Room-A
D signal
D signal
7 8 Current BP 3 Room-B
D signal
D signal
7 9 Current BP 3 Room-C
D signal
D signal
80
8 1 Gas short error counter (NGAS) Counter
8 2 Discharge pipe temperature error counter (NOT) Counter
8 3 HPS action counter (NHPS) Counter
8 4 Upper fan lock error counter (NF1LOCK) Counter
8 5 Upper fan OCP error counter (NF1OCP) Counter
8 6 Lower fan lock error counter (NF2LOCK) Counter
8 7 Lower fan OCP error counter (NF2OCP) Counter
8 8 Supply voltage line error counter (NDC) Counter
8 9 Output current line electronic thermal anti-stall counter (NTH) Counter
9 0 Electronic thermal anti-stall counter with position detection waveform (NST) Counter
9 1 Box temperature rise counter (NBOX) Counter
9 2 Radiation fin temperature rise counter (NFIN) Counter
9 3 Compressor lock counter (NCOMP) Counter
9 4 AC current sensor line error counter (NCT) Counter
9 5 Total input over-current error counter (NIINT) Counter
9 6 INV input over-current error counter (NIINV) Counter
9 7 Anti-freeze action counter (NTOU) Counter
9 8 Peak cut action counter (NPC) Counter
9 9 BP indoor anti-freeze error counter (NCOLD HU) Counter