Specifications Si18-201
26 Specifications
"
Ceiling Mounted Cassette Type (SkyAir)
Refer to Engineering Data Book.
"
3.75kW Class · 5.2kW Class
50Hz 220-230-240V / 60Hz 220-230V
Model FHYC35KVE9 FHYC50KVE9
Rating Capacity kW 3.75 5.2
Front Panel Color White
Air Flow
Rates
m³/min
H 14.0 15.0
L 10.0 11.0
cfm
H 494 530
L 353 388
Fan
Type Turbo Fan
Motor Output W 45
Speed Steps 2 Steps and Auto
Air Filter Resin Net (with Mold Resistant)
Running Current
(Rated) A 0.8 - 0.8 / 0.9
Power Consumption
(Rated) W 140 - 140 / 161
Power Factor
% 79.5 - 72.9 / 81.3
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 230×840×840
Package Dimensions mm 305×930×920
Weight kg 24
Gross Weight kg 29
Operation Sound dBA
H33
L29
Heat Insulation Both Liquid and Gas Pipes
Piping
Connection
Liquid mm
φ
6.4
Gas mm
φ
12.7
φ
15.9
Drain mm
φ
25.0
"
6.15kW Class · 7.7kW Class
50Hz 220-230-240V / 60Hz 220-230V
Model FHYC60KVE9 FHYC71KVE9
Rating Capacity kW 6.15 7.7
Front Panel Color White
Air Flow
Rates
m³/min
H 19.0
L 14.0
cfm
H 671
L 494
Fan
Type Turbo Fan
Motor Output W 45
Speed Steps 2 Steps and Auto
Air Filter Resin Net (with Mold Resistant)
Running Current
(Rated) A 0.9 - 0.9 / 1.0
Power Consumption
(Rated) W 161 - 161 / 181
Power Factor
% 81.3 - 74.5 / 82.3
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 230×840×840
Package Dimensions mm 305×930×920
Weight kg 24
Gross Weight kg 29
Operation Sound dBA
H35
L30
Heat Insulation Both Liquid and Gas Pipes
Piping
Connection
Liquid mm
φ
6.4
φ
9.5
Gas mm
φ
15.9
Drain mm
φ
25.0
Conversion Formulae
kcal/h=kW×860