EasyManua.ls Logo

Daikin FTK35JVE9 - 2.8 Removal of 4-way Valve

Daikin FTK35JVE9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Si18-201 Outdoor Unit
Removal Procedure 325
7. Detaching the filter PCB
1
The filter PCB is
located as shown at
right.
2
Disconnect all the
connectors and remove
the four locking guard
spacers. Take out the
filter PCB.
3
Remove the four
screws and take out
the reactors.
4
Lay and dress the
reactor harnesses.
Step Procedure Points

Table of Contents

Related product manuals