SiENBE04-507A Indoor Unit
Removal Procedure 163
Step Procedure Points
5
6
7
8
Remove the drip proof
plate by removing the
screw.
Replace the heat
exchanger thermistor.
Disconnect the earth
wire by removing the
screw.
Remove the screw of
the electrical box.
Put any excess wires behind
the power supply lead wire.
Use care not to lose the
retainer of thermistor.
Retainer of
thermistor
Heat exchanger
thermistor
Drip proof plate
Heat exchanger
thermistor
Retainer of
thermistor
Earth wire