EasyManua.ls Logo

Daikin FTKS25D3VMW(L) - Page 179

Daikin FTKS25D3VMW(L)
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indoor Unit SiENBE04-507A
170 Removal Procedure
2
Lift up the bottom of the
control PCB and pull it
out.
When mounting the control
PCB, make sure that it is
fixed by upper hooks.
3
The figures show the
names of the PCB
component parts.
Lead-free solder (PbF) is
used for the PCB. When
replacing the PCB, use the
specific solder and soldering
iron.
[S1] To DC fan motor
[S6] To swing motor
[S21] HA connector
[S26] To display PCB
[S28] To signal receiver PCB
[S32] To heat exchanger
thermistor
[S35] To INTELLIGENT EYE
PCB
Step Procedure Points
Fixing
hook
Fixing hook
Fuse cap
Glass tube fuse
(R4288)
Varistor (w/cap)
[S1]
Fuse
(holder type
w/cap)
[S6]
[S26]
[S28]
[S32]
[S35]
[S21]
[S29]
[S27]
[S36]
SW1
RTH1
LED 1
(Green)
LED 2
(Yellow)
LED 3
(Green)

Table of Contents