SiENBE04-507A Indoor Unit
Removal Procedure 173
3. Removing the crank
assembly
1
Remove the screw of
the crank assembly.
2
Remove the crank
assembly by
unfastening the hook.
3
The figure shows the
position of the hook
when the crank
assembly has been
removed.
4. How to connect the drain
hose in right piping
1
Pull out the drain hose
from its right side
connection.
Step Procedure Points
Crank assembly
Hook
Hook inserting part
Drain hose