Instruction SiENBE12-713
188 System Configuration
NOTES
"
Turn the breaker ON
• Turning ON the breaker opens the flap, then closes it again. (This is a normal procedure.)
"
Tips for saving energy
• Be careful not to cool (heat) the room too much.Keeping the temperature setting at a
moderate level helps save energy.
• Cover windows with a blind or a curtain.Blocking sunlight and air from outdoors
increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every two weeks.
"
Please note
• The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
• Use the air conditioner in the following conditions.
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
Recommended temperature setting
For cooling:26°C – 28°C
For heating:20°C – 24°C
Mode Initial setting Selectable range
COOL Outdoor temperature: [2MK(X)S40/50] 10 to 46°C
[2MK(X)S52] –10 to 46°C
[3/4/5MK(X)S] –10 to 46°C
[RK(X)S –10] to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the
operation.(In multi system, it may work to stop
the operation of the out-door unit only.)
• Condensation may occur on the indoor unit and
drip.
HEAT Outdoor temperature: [2MXS40] –10 to 24°C
[2MXS52] –15 to 24°C
[3/4/5MXS] –15 to 15.5°C
[RXS] –15 to 24°C
Indoor temperature: 10 to 30°C
• A safety device may work to stop the operation.
DRY Outdoor temperature: [2MK(X)S40/50] 10 to 46°C
[2MXS50/52] –10 to 46°C
[3/4/5MK(X)S] –10 to 46°C
[RK(X)S] –10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and
drip.