Loading...
Si041352ED PCBs
Removal Procedure 11
9
10
Unfasten the 2 hooks
and remove the signal
receiver PCB.
Disconnect the
connector [S48].
[S48]: control PCB
2. Remove the
INTELLIGENT EYE
sensor PCB.
Some models do not have
the INTELLIGENT EYE
sensor ASSY.
1 Unfasten the 4 hooks
and remove the
INTELLIGENT EYE
sensor ASSY.
2 Remove the sensor.
When reassembling, set the
sensor at the position where
it clicks. Otherwise, the
sensor is not completely set.
3
4
Unfasten the 2 hooks
and detach the
INTELLIGENT EYE
sensor PCB.
Disconnect the
connector [S36].
[S36]: control PCB
Step Procedure Points
(R25310)
[S48]
Signal receiver PCB
Hook
(R9523)
Hook
Hook
INTELLIGENT EYE
sensor ASSY
(R24486)
Sensor
(R24487)
Shield plate
Hook
INTELLIGENT EYE
sensor PCB
[S36]