REMOVAL
PROCEDURE
SERVICE MANUAL
Indoor Unit
Non-Inverter
Wall Mounted Type
1.5/2.0/2.5/3.5 kW Class
Si041265EC
Question and Answer IconNeed help?

Do you have a question about the Daikin FTNE25MV1 and is the answer not in the manual?

Daikin FTNE25MV1 Specifications

General IconGeneral
BrandDaikin
ModelFTNE25MV1
CategoryAir Conditioner
LanguageEnglish

Summary

Air Filters and Front Panel Removal

Remove Air Filters

Procedure to remove the air filters by opening the front panel to its stopping position.

Remove Front Panel

Procedure to remove the front panel by pushing shafts towards the inside to release it.

Front Grille Removal

Remove Screws and Hooks

Procedure to prepare the front grille for removal by unscrewing and unfastening its hooks.

Remove Front Grille

Final step to detach the front grille after all fasteners are released.

Horizontal and Vertical Blades Removal

Remove Horizontal Blades

Procedure to detach horizontal blades by unfastening shafts and slightly bending them.

Remove Vertical Blade ASSYS

Procedure to remove vertical blade assemblies by unfastening their respective hooks.

Electrical Box, PCBs, and Swing Motor Removal

Remove Electrical Box

Procedure to remove the main electrical box by disconnecting wires and screws.

Remove Shield Plate and Box Cover

Procedure to remove the shield plate and the electrical box cover.

Remove Signal Receiver and Control PCBs

Procedure to disconnect connectors and remove signal receiver and control PCBs.

Remove Swing Motor

Procedure to detach the swing motor by removing its mounting screws.

Indoor Heat Exchanger Removal

Prepare for Heat Exchanger Removal

Steps to remove screws, disconnect drain hose, and prepare piping.

Remove Indoor Unit from Plate

Procedure to detach the indoor unit from its installation plate.

Remove Piping Fixture and Auxiliary Piping

Procedure to unfasten the piping fixture and pull out the auxiliary piping.

Remove Heat Exchanger

Procedure to unfasten hooks on both sides and remove the indoor heat exchanger.

Fan Motor and Fan Rotor Removal

Remove Right Side Plate

Procedure to remove screws and unfasten the hook to detach the right side plate.

Remove Fan Motor and Fan Rotor

Procedure to loosen the screw and remove the fan motor and fan rotor.

Remove Left Side Plate and Bearing

Procedure to remove the left side plate and the bearing.