Specifications SiUS04-702
6 Specifications
60
Hz
230V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Units FTXS24DVJU
Outdoor Units
RX24FVJU
Cooling Heating
Capacity
Rated (Min.~Max.)
Btu/h 22,000 (7,500~22,000) 24,000 (7,500~25,400)
Moisture Removal Pt/h 6.3
Running Current (Rated) A 11.35 12.43
Power Consumption Rated
(Min.~Max.)
W 2,600(450~2,600) 2,850(450~3,320)
Power Factor % 99.6 99.7
EER (Rated)
Btu/h·W
8.5
COP (Rated) W/W 2.47
Energy
Efficiency
SEER 13.0
HSPF 7.7
Piping
Connections
Liquid inch
φ
1/4
Gas inch
φ 5
/8
Drain inch
φ
11/16
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length feet 98.4
Max. Interunit Height Difference feet 65.6
Chargeless feet 33
Amount of Additional Charge of
Refrigerant
oz/ft 0.22
Indoor Unit FTXS24DVJU
Front Panel Color White
Air Flow Rate cfm (m³/min)
H 536(15.2) 586(16.6)
M 473(13.4) 532(15.1)
L 409(11.6) 477(13.5)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.20
Power Consumption (Rated) W 45
Power Factor % 97.8
Temperature Control Microcomputer Control
Dimensions (H×W×D) inch 11-7/16×41-5/16×9-3/8
Packaged Dimensions (H×W×D) inch 13-1/4×45-3/16×14-7/16
Weight Lbs 26.5
Gross Weight Lbs 38.0
Operation
Sound
H/M/L dBA 46 / 42 / 37 46 / 42 / 37
Outdoor Unit RX24FVJU
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC45EXD
Motor Output W 1,900
Refrigerant
Oil
Model FVC50K
Charge oz 25.2
Refrigerant
Model R-410A
Charge Lbs 3.75
Air Flow Rate cfm (m³/min)
H 1,752(49.6) 1,465(41.5)
L 1,529(43.3) 1,398(39.6)
Fan
Type Propeller
Motor Output W 53
Running Current (Rated) A 11.15 12.23
Power Consumption (Rated) W 2,555 2,805
Power Factor % 99.7 99.7
Dimensions (H×W×D) inch 28-15/16×32-1/2×11-13/16
Packaged Dimensions (H×W×D) inch 31-7/16×37-15/16×15-3/8
Weight Lbs 121.0
Gross Weight Lbs 137.0
Operation
Sound
H / L dBA 54 / — 54 / —
Drawing No. 3D056383
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Heating Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25ft