SiBE041134 Outdoor Unit
Removal Procedure 143
2.2 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Disconnect the
connector for the
overload protector
[S40].
Preparation
Remove the panels and
disconnect the connector for
the fan motor according to
the “Removal of Outer
Panels / Fan Motor”.
2
Disconnect the
connector for the four
way valve coil [S80].
3
Disconnect the 2
connectors for the
reactor.
The colors of the harnesses
(white or brown) do not
matter to the position of the
connector.
(R11846)
[S40]
(R11848)
[S80]
(R11844)