  • S
    stephanie26Aug 14, 2025
    What to do if Daikin FTXS60FV1B Air Conditioner does not operate and OPERATION lamp is off?
    • M
      Monique ChavezAug 14, 2025
      If your Daikin Air Conditioner isn't working and the OPERATION lamp is off, check a few things: first, see if a breaker has tripped or a fuse has blown. Next, verify whether there's a power failure in your area. Also, make sure that batteries are correctly installed in the remote controller, and confirm that the timer setting is accurate.
  • S
    Susan HurstAug 17, 2025
    What to do if Daikin FTXS60FV1B operation stops suddenly and OPERATION lamp flashes?
    • K
      Karen CarrAug 17, 2025
      If your Daikin Air Conditioner stops suddenly and the OPERATION lamp is flashing, check if the air filters are clean and whether anything is blocking the air inlet or outlet of the indoor and outdoor units. Clean the air filters or remove any obstacles, then turn the breaker OFF. Also, ensure that the operation modes are the same for all indoor units connected to the outdoor units in the multi system.
  • K
    karla17Aug 21, 2025
    Why Daikin FTXS60FV1B operation does not start soon?
    • K
      Karen BarnesAug 21, 2025
      If your Daikin Air Conditioner doesn't start immediately, please wait for about 3 minutes.
  • L
    Linda AllenAug 25, 2025
    Why hot air does not flow out soon after the start of heating operation of Daikin Air Conditioner?
    • M
      Melissa SchultzAug 25, 2025
      If hot air does not flow out immediately after starting the heating operation of your Daikin Air Conditioner, allow 1 to 4 minutes for the hot air to begin flowing.
  • X
    xwalshAug 27, 2025
    Why mist comes out of the indoor unit of Daikin FTXS60FV1B?
    • J
      Janet GarciaAug 27, 2025
      Mist may come out of the indoor unit of your Daikin Air Conditioner when the air in the room is cooled into mist by the cold airflow during cooling operation.
  • M
    marcuswilliamsAug 30, 2025
    What to do if Daikin Air Conditioner operation stopped suddenly and OPERATION lamp is on?
    • M
      morristammyAug 30, 2025
      If your Daikin Air Conditioner operation stopped suddenly but the OPERATION lamp is still on, it should automatically resume operation in about 3 minutes.
  • C
    conwayjasmineSep 3, 2025
    What to do if abnormal functioning happens during Daikin FTXS60FV1B operation?
    • G
      Gary ScottSep 3, 2025
      If you experience abnormal functioning during the operation of your Daikin Air Conditioner, try turning the breaker OFF, then turn it back ON, and attempt to operate the air conditioner using the remote controller.
  • D
    Douglas DickersonSep 6, 2025
    Why the outdoor fan rotates while Daikin FTXS60FV1B Air Conditioner is not in operation?
    • J
      Julie WashingtonSep 6, 2025
      If the outdoor fan of your Daikin Air Conditioner is rotating even when the unit is not in operation, it could be for system protection when the outdoor temperature is very high.
  • M
    mary91Sep 9, 2025
    Why the heating operation stops suddenly and a flowing sound is heard in Daikin Air Conditioner?
    • C
      carolynpetersonSep 10, 2025
      If the heating operation of your Daikin Air Conditioner stops suddenly and you hear a flowing sound, please wait for about 4 to 12 minutes.

Daikin FTXS60FV1B Specifications

General IconGeneral
Cooling Capacity6.0 kW
Heating Capacity7.0 kW
Coefficient of Performance (COP)4.00
Weight (Indoor Unit)12 kg
TypeSplit
Power Supply230V/50Hz
RefrigerantR32
Indoor Unit Noise Level19 dB (Low)