EasyManua.ls Logo

Daikin FTXS71LVMA - Control PCB Removal

Daikin FTXS71LVMA
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Si041144 Removal of PCBs
Removal Procedure 17
4. Remove the control PCB.
1
Unfasten the 3 hooks.
Lift up and remove the
control PCB.
2
Pull out the earth wire
from the terminal board.
3
Pull out the terminals
from the terminal board.
Step Procedure Points
(R9517)
Hook
Hook
Control PCB
(R17243)
Earth
wire
(R9519)
Terminal

Other manuals for Daikin FTXS71LVMA

Related product manuals