SiBE01-503 Outdoor Unit
Removal Procedure 101
2.6 Removal of Partition Plate
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. To remove the partition plate.
1
Disengage the lead
wires from the wire clip.
2
Remove the two screws
fixing the partition plate.
3
Pull the partition plate
upward to remove.