DAIKIN ROOM AIR CONDITIONER
Operation Manual
R410A R32
FVXS25FV1B FVXM25FV1B
FVXS35FV1B FVXM35FV1B
FVXS50FV1B FVXM50FV1B
3PEN477071-1A.book Page 1 Thursday, March 30, 2017 1:28 PM

Other manuals for Daikin FVXM50FV1B

Questions and Answers

  • J
    Jennifer EdwardsAug 18, 2025
    What to do if my Daikin Air Conditioner is not cooling or heating well?
    • S
      Scott AtkinsAug 18, 2025
      If your Daikin Air Conditioner isn't cooling or heating effectively, consider these points: * Check if the air filters are clean. * Ensure that nothing is blocking the air inlet or outlet of either the indoor or outdoor units. * Verify that the temperature setting is appropriate for your needs. * Make sure all windows and doors are properly closed. * Confirm that the airflow rate and direction are set correctly.
  • K
    Kevin WilliamsAug 21, 2025
    How to fix a Daikin FVXM50FV1B Air Conditioner that won't turn on?
    • E
      edward65Aug 22, 2025
      If your Daikin Air Conditioner isn't turning on and the OPERATION lamp is off, check the following: * Has a breaker tripped or a fuse blown? * Is there a power failure? * Are batteries correctly installed in the remote controller? * Is the timer setting correct?
  • H
    Heather ParkerAug 25, 2025
    Why won't my Daikin FVXM50FV1B heat when I try to set it?
    • C
      Charles SmithAug 26, 2025
      If your Daikin Air Conditioner won't accept the heating instruction, check the specifications of the outdoor unit. If it's a cooling-only model, set the remote controller accordingly using the cooling-only/heat pump switch.
  • J
    Jeffrey JohnstonAug 28, 2025
    What to do if my Daikin Air Conditioner is malfunctioning?
    • E
      Eric NguyenAug 28, 2025
      If your Daikin Air Conditioner is experiencing an abnormal function during operation, turn the breaker OFF, then turn it back ON. After that, try operating the air conditioner using the remote controller.
  • T
    Travis BrownAug 31, 2025
    Why is my Daikin Air Conditioner remote controller display not working correctly?
    • D
      dawn78Aug 31, 2025
      If you're experiencing issues with your Daikin Air Conditioner's remote controller display, such as no signals, low sensitivity, low contrast, a blacked-out display, or uncontrolled behavior, replace all the batteries with new AAA alkaline batteries. If there's a reset button, press it after replacing the batteries.
  • T
    Terry NguyenSep 3, 2025
    Why doesn't the Daikin Air Conditioner ON/OFF TIMER work as set?
    • J
      Joshua BarnesSep 3, 2025
      If the ON/OFF TIMER on your Daikin Air Conditioner isn't working as expected, check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time. If they are, change or disable the settings in the WEEKLY TIMER.
  • E
    Emily WilsonSep 7, 2025
    How to stop noise interference from my Daikin Air Conditioner affecting TV or radio?
    • L
      lfernandezSep 7, 2025
      To minimize noise interference from your Daikin Air Conditioner affecting television or radio sets: * Ensure that no television or radio sets are located close to the indoor unit. * Keep television or radio sets at least 1 meter away from the indoor unit.
  • G
    Gregory WilsonSep 12, 2025
    Why can't I select heating on my Daikin FVXM50FV1B, even though it's a heat pump model?
    • J
      Jeremy GarciaSep 12, 2025
      If you cannot select heating on your Daikin Air Conditioner, even though it is a heat pump model, set the remote controller so that it is for a heat pump model by using the cooling only/heat pump switch on the remote controller.
  • S
    Samantha HerreraNov 14, 2025
    Why does my Daikin FVXM50FV1B Air Conditioner stop suddenly and the operation lamp flashes?
    • R
      Ryan HartmanNov 14, 2025
      The Daikin Air Conditioner might stop suddenly and the operation lamp might flash due to several reasons. First, check if the air filters are clean and if there are any obstructions blocking the air inlet or outlet of the indoor and outdoor units. Clean the filters or remove any obstacles, then turn the breaker OFF and back ON. Try operating the air conditioner with the remote controller again. If the lamp continues to flash, it is recommended to contact the service shop where you purchased the air conditioner. Also, if you're using a multi-system, ensure all indoor units connected to the outdoor units have the same operation modes. If not, set them all to the same mode and check if the lamps still flash. When the operation mode is in 'AUTO', set all indoor unit operation modes to 'COOL' ...

Summary

Safety Precautions

Installation Site Selection

Guidance on selecting an appropriate location for the air conditioner unit.

Names of Parts

Indoor Unit Components

Identifies and labels the various parts of the indoor air conditioning unit.

Outdoor Unit Components

Identifies and labels the various parts of the outdoor air conditioning unit.

AUTO DRY COOL HEAT FAN Operation

Starting and Stopping Operation

Steps to initiate, pause, and resume air conditioner operation using the remote.

Temperature Setting Adjustment

How to adjust the desired temperature for different operating modes.

Airflow Rate Adjustment

How to change the fan speed settings for different modes.

Adjusting the Airflow Direction

Horizontal Flap Control

Instructions for adjusting the horizontal airflow direction using the remote.

Vertical Louver Adjustment

How to manually adjust the vertical airflow direction using the unit's knob.

Powerful Operation

Initiating Powerful Operation

Steps to activate the high-speed cooling/heating mode for maximum effect.

Cancelling Powerful Operation

How to deactivate the POWERFUL operation mode.

Outdoor Unit Quiet Operation

Starting Quiet Outdoor Operation

Steps to activate the mode that reduces outdoor unit noise.

Econo Operation

Timer Operation

Weekly Timer Operation

Setting the Weekly Timer

Step-by-step guide to programming daily ON/OFF times and temperatures.

Trouble Shooting

Refrigerant Leakage Sensor Issues

Explains abnormal operations related to the refrigerant leakage sensor.

Critical Warning and Actions

Safety warnings for abnormal conditions and actions to take.

Fault Diagnosis

Remote Controller Diagnosis

How to use the remote controller to diagnose system faults and error codes.

System Error Code Explanations

Detailed list and meaning of system error codes displayed on the unit.

Daikin FVXM50FV1B Specifications

General IconGeneral
Cooling Capacity5.0 kW
Power Supply220-240V, 50Hz
RefrigerantR32
Seasonal Energy Efficiency Ratio (SEER)6.1
Indoor Noise Level19 dB (Low)